Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

04/03/2014

Applicant:

DANNY NG, NENA NG, & NOLA YOUNG, OCCUPANT UNIT # 404

Description:

Water heater, stairs, cooler support, etc. 4/15/14-Owner called in to advise he has permits for issues. Transferred to Inspector Pumphery's VM.

Outstanding Inspections

Case Number: T14DV02141
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
06/13/2014 NPO(PL)-WATER HEATERS PUMPHREY Item closed
06/13/2014 NPO(DL)-DILAPIDATED STRUCTURE PUMPHREY Item closed
06/13/2014 NPO - EXT. BUILDING MAINTENANC PUMPHREY Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV02141
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
03/19/2014 INSP - INITIAL CODE ENFORCMENT PUMPHREY Approved Water heater lacks cold water shutoff valve; broken window; access steps are not structurally sound, are balanced on ungrouted CMUs; evap cooler stand and roof sides need weatherproofing; rear door lacks framing and access steps;
06/13/2014 INSP - FOLLOW UP CODE ENFORCE PUMPHREY Approved Compliant; painting completed.

Outstanding Case Activity Conditions

Date Name Approved
04/03/2014 T.C. CH. 16, SEC. 16-12(A)(4) WINDOWS, SKYLIGHTS, AND DOORS: Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. Not Approved
04/03/2014 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Not Approved
04/03/2014 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. Not Approved
04/03/2014 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. Not Approved

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T14DV02141
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
04/15/2014 CONTACTED BY PHONE
04/03/2014 NOTICE OF VIOLATION ISSUED
04/30/2014 RESEARCH

Documents

File Name Document Type  
615 W ALTURAS ST - UNIT 404 - NOV.PDF DOCUMENTS VIEW