Case: T14DV02092
Case Details
Entered Date:
04/02/2014
Applicant:
NG TR 1/3 & NG NENA 1/3 & YOUNG NOLA 1/3 DANNY F. NG TR
Description:
Broken windows, cooler needs work, sewer vent
Case Violations
Case Number: T14DV02092
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
Violation Date | Code Statue |
---|---|
04/02/2014 | T.C. Ch. 6, IRC adopted. R311.5.3.1 RISER HEIGHT. The maximum riser height shall be 7 3/4 inches (196 mm). The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm).T.C. Ch. 6, IRC adopted. R311.7.5.1 RISER HEIGHT. The maximum riser height shall be 7 ¾ inches (196 mm). The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). Risers shall be vertical or sloped from the underside of the nosing of the tread above at an angle not more than 30 degrees from the vertical. Open risers are permitted provided that the opening between treads does not permit the passage of a 4-inch diameter sphere. |
04/02/2014 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
04/02/2014 | T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced. |
04/02/2014 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
Outstanding Inspections
Case Number: T14DV02092
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/14/2014 | NPO - UNSECURED BUILD OR STRUC | STEVENS | Item closed | |
05/14/2014 | NPO(PL)-PLUMBING SYSTEM & FX | STEVENS | Item closed | |
05/14/2014 | NPO(PL)-SEWAGE DISPOSAL (SYS) | STEVENS | Item closed | |
05/14/2014 | NPO(HC)-COOLING | STEVENS | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV02092
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/02/2014 | INSP - INITIAL CODE ENFORCMENT | STEVENS | Approved | At site, broker windows on the east side of trailer, Cooler not working properly. Sewer vent is broken, needs to extened above the roof, open clean out, needs a cap. Access steps are mis-matched. F/U 30 days. |
05/14/2014 | INSP - FOLLOW UP CODE ENFORCE | STEVENS | Approved | At site, issues abated, close case. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T14DV02092
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
04/03/2014 | CONTACTED BY MAILING |
04/03/2014 | NOTICE OF VIOLATION ISSUED |
05/15/2014 | VIOLATION CLOSED |