Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

02/10/2014

Applicant:

RIDGEWOOD APARTMENTS LLC

Description:

Fire Damage #K

Case Violations

Case Number: T14DV00763
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 6
Violation Date Code Statue
02/10/2014 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
02/10/2014 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (5) When a structure is equipped with a gas supply system, it must be installed and maintained in a safe, hazard-free condition.
02/10/2014 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (4) All plumbing fixtures shall be connected to a public sewer system or to an approved private sewage disposal system, with the connections free from leaks, blockages, or other defects. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water necessary for its normal operation.
02/10/2014 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
02/10/2014 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.
02/10/2014 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T14DV00763
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
09/25/2014 NPO(EL)-MAIN/PANEL/SUB/DISCONT SMITH Item closed
09/25/2014 NPO(PL)-PLUMBING SYSTEM & FX SMITH Item closed
09/25/2014 NPO(PL)-GAS SUPPLY/CONNECT SMITH Item closed
09/25/2014 NPO - EXT. BUILDING MAINTENANC SMITH Item closed
09/25/2014 NPO - INT. BUILDING MAINTENANC SMITH Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV00763
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/07/2014 INSP - INITIAL CODE ENFORCMENT LOPEZ Approved Was called out to a fire call from communications. unit had total loss to kitchen and living room and exterior porch, also smoke damage though out the unit. follow up 30 days.
09/25/2014 INSP - FOLLOW UP CODE ENFORCE SMITH Approved Permit has gobne final Case Closed.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T14DV00763
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
02/10/2014 CONTACTED IN PERSON
02/12/2014 NOTICE OF VIOLATION ISSUED
04/28/2014 PERMIT ISSUED - T##XX#####
09/25/2014 VIOLATION CLOSED
09/29/2014 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
02/12/2014 STRUCTURE SECURED BY ???

Documents

File Name Document Type  
3402 S PANTANO RD_UNIT K_E DOCS.PDF DOCUMENTS VIEW