Case: T14DV00398
Case Details
Entered Date:
01/22/2014
Applicant:
BAMHP LLC ATTN: RONALD E. & SUZANNE SALISBURY
Description:
Raw sewage spilling out into the yard. Broken pipe. Water heater not stable in area. The flooring for the water heater is bad and weak. There is a worry the water heater will fall through the flooring. The smell is horrible. Resident does not let her kids out in the yard. Sewage has been an issue since mid December 2013.
Case Violations
Case Number: T14DV00398
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 01/23/2014 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
| 01/23/2014 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 01/23/2014 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (5) When a structure is equipped with a gas supply system, it must be installed and maintained in a safe, hazard-free condition. |
| 01/23/2014 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 01/23/2014 | T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
Outstanding Inspections
Case Number: T14DV00398
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/13/2014 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | STEVENS | Item closed | |
| 12/13/2014 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | STEVENS | Item closed | |
| 12/13/2014 | NPO(PL)-PLUMBING SYSTEM & FX | STEVENS | Item closed | |
| 12/13/2014 | NPO(PL)-SEWAGE DISPOSAL (SYS) | STEVENS | Item closed | |
| 12/13/2014 | NPO(PL)-WATER HEATERS | STEVENS | Item closed | |
| 12/13/2014 | NPO(HC)-HEATING & VENTILATION | STEVENS | Item closed | |
| 12/13/2014 | NPO - EXT. BUILDING MAINTENANC | STEVENS | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV00398
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2014 | INSP - INITIAL CODE ENFORCMENT | STEVENS | Approved | At site, spoke to tenant. Hot water leak at water heater closet. Floor around water heater rotting out. Water heater not properly vented. There is a lot of water leaking around the 3" waste pipe when the toilet is flushed. There's a hole in the bathroom floor and the floor around the furnance is collapsing. Outlet in bedroom not secured to wall. Water leak at the roof is coming in thru the hallway outlet. Stove exhaust fan doesn't work and has wires hanging through the exhaust hole. Some windows were screwed shut. F/U 30 days. |
| 12/12/2014 | INSP - FOLLOW UP CODE ENFORCE | STEVENS | Approved | At site, spoke to park manager. All code repairs have been made to the trailer. Close case. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T14DV00398
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 01/24/2014 | NOTICE OF VIOLATION ISSUED |
| 12/13/2014 | VIOLATION CLOSED |