Case: T14DV00346
Case Details
Entered Date:
01/21/2014
Applicant:
WERTH REALTY. ATTN MANAGER KARRY SMOCK
Description:
Fire inside apartment. Fire code F140210067.
Case Violations
Case Number: T14DV00346
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 01/22/2014 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
Outstanding Inspections
Case Number: T14DV00346
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/25/2014 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VALDEZ | Item closed | |
| 02/25/2014 | NPO - INT. BUILDING MAINTENANC | VALDEZ | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV00346
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/21/2014 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | ONSITE INSPECTION: A KITCHEN FIRE TOOK PLACE ON 1-20-2014 AROUND 5:30 PM. THE TENANT DID EXTINGUISH THE FIRE. THE TENANT CALLED TFD ON THE MORNING OF THE 1-21-2014. TFD ACTION WAS THEY DISCONNECTED THE MICROWAVE AND THE STOVE AND THEN CALL US. THE INSPECTION RESULTS ARE THERE IS DAMAGE TO THE MICROWAVE AND THE DRYWALL HAS SMOKE DAMAGE IN THE WALLS AND CEILING. NO STRUCTURAL DAMAGE TO THE UNIT. THE RECEPTACLE TO THE MICROWAVE AND THE STOVE DO NOT HAVE A PHYSICAL DAMAGE. I DID TURN THE CIRCUIT BREAKERS OFF THE STOVE AND THE KITCHEN RECEPTACLES. I DID NOTICE THAT NONE OF THE MAIN DISCONNECTS HAVE LABELING ON THE UNITS OR THE CIRCUIT BREAKERS. THE MAINTENANCE MAN DID HELP ME ISOLATE THE BREAKERS. FOLLOW UP INSPECTION DUE IN 10 DAYS FOR THE ELECTRICAL. ALL DOCUMENTS HAVE BEEN SCANNED INTO SIRE |
| 02/25/2014 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ALL REPAIRS HAVE BEEN COMPLETED CLOSE CASE |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 01/23/2014 | 2011 NATIONAL ELECTRIC CODE ARTICLE 408.4 FIELD IDENTIFICATION REQUIRED. (A) CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION. EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. SPARE POSITIONS THAT CONTAIN UNUSED OVER CURRENT DEVICES OR SWITCHES SHALL BE DESCRIBED ACCORDINGLY. THE IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON THE FACE OR INSIDE OF THE PANEL DOOR IN THE CASE OF A PANEL BOARD, AND LOCATED AT EACH SWITCH OR CIRCUIT BREAKER IN A SWITCH BOARD. NO CIRCUIT SHALL BE DESCRIBED IN A MANNER THAT DEPENDS ON TRANSIENT CONDITIONS OF OCCUPANCY. 2011 NATIONAL ELECTRIC CODE ARTICLE 110.22 IDENTIFICATION OF DISCONNECTING MEANS. (A) GENERAL. EACH DISCONNECTING MEANS SHALL BE LEGIBLY MARKED TO INDICATE ITS PURPOSE UNLESS LOCATED AND ARRANGED SO THE PURPOSE IS EVIDENT. THE MARKING SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED | Not Approved |
Completed Activity Special Conditions
Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T14DV00346
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 01/22/2014 | CONTACTED BY PHONE |
| 01/22/2014 | CONTACTED IN PERSON |
| 01/24/2014 | CONTACTED BY MAILING |
| 01/22/2014 | NOTICE OF VIOLATION ISSUED |
| 02/25/2014 | VIOLATION CLOSED |
| 01/21/2014 | 8-5 CITY COMM EMERGENCY |