Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T14DV00067
Case Details
Entered Date:
01/07/2014
Applicant:
DANNY NG, NENA NG, & NOLA YOUNG, OCCUPANT
Description:
Min housing inspection - Sleepy Hollow TP
Case Violations
Case Number: T14DV00067
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
Violation Date | Code Statue |
---|---|
01/07/2014 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
01/07/2014 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (4) All plumbing fixtures shall be connected to a public sewer system or to an approved private sewage disposal system, with the connections free from leaks, blockages, or other defects. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water necessary for its normal operation. |
01/07/2014 | T.C. Ch. 16, Sec. 16-12(e) ACCESSORY STRUCTURES. All accessory structures, including but not limited to detached garages, fences and walls, must be structurally sound and free of disrepair. Examples of disrepair include missing slats, posts or blocks, or damage, deterioration or rot. Fences and walls cannot be constructed or covered with materials not designed or commonly used for that purpose, such as pallets and tarps. Fences and walls must be properly anchored so as not to be in danger of failure or collapse. |
01/07/2014 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
Outstanding Inspections
Case Number: T14DV00067
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/08/2014 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | PUMPHREY | Item closed | |
12/19/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | PUMPHREY | Item initialized | |
12/19/2013 | NPO(PL)-GAS SUPPLY/CONNECT | PUMPHREY | Item initialized | |
12/19/2013 | NPO(PL)-WATER HEATERS | PUMPHREY | Item initialized | |
12/19/2013 | NPO(DL)-DILAPIDATED STRUCTURE | PUMPHREY | Item initialized | |
12/19/2013 | NPO - EXT. BUILDING MAINTENANC | PUMPHREY | Item initialized |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV00067
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/07/2014 | INSP - INITIAL CODE ENFORCMENT | PUMPHREY | Approved | Illegal electrical connection tapped into 30 amp breaker on pedestal (side); sewer cleanout missing cap; gas water heater TRPV valve capped, no cold water shutoff, leaking line, plastic line incorrectly connected to a copper line; no apparent hot water available because there is no gas service; shed with stucco exterior has dilapidated roof, broken wind, under 200 sq ft unattached; broken window; A/C window unit incorrectly using extension cord. |
05/08/2014 | INSP - FOLLOW UP CODE ENFORCE | PUMPHREY | Approved | Complaint. |
Outstanding Case Activity Conditions
Date | Name | Approved |
01/07/2014 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. | Not Approved |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T14DV00067
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
01/07/2014 | NOTICE OF VIOLATION ISSUED |
06/20/2014 | VIOLATION CLOSED |
01/07/2014 | RESEARCH |