Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

12/30/2013

Applicant:

PAUL BRIEN

Description:

FIRE DAMAGE TO BUILDING & ELECTRICAL SERVICE

Outstanding Inspections

Case Number: T13DV09467
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
12/30/2013 NPO(EL)-MAIN/PANEL/SUB/DISCONT JVALDEZ Item initialized
12/30/2013 NPO(PL)-GAS SUPPLY/CONNECT JVALDEZ Item initialized
12/30/2013 NPO(DL)-DILAPIDATED STRUCTURE JVALDEZ Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV09467
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/29/2013 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved EMERGENCY CALL OUT BY TFD; THERE WAS FIRE DAMAGE TO THE BUILDING EXTERIOR SHEATHING WHICH IS A 2X6 STUD WALL. TWO WINDOWS WERE DAMAGED AND PART OF THE WALL DIRECTLY BEHIND THE DISCONNECTS. ELECTRICAL DAMAGE WAS TO UNIT'S F DISCONNECT WHICH CAUSE THE ALL INTERIOR COMPONENTS SUCH AS BREAKERS AND CONDUCTORS TO MELT THE HEAT DAMAGE CONTINUED TO THE VERTICAL GUTTER BOX WERE ALL THE ALUMINUM FEEDERS TO UNIT'S E, F, G AND H WERE SEVERELY BURNT AND SOME OF THEM MELTED. TEP'S TRANSFORMER ALSO DAMAGED AND LATER THAT MORNING REPLACED. THE POWER REMAINS OFF THE ABOVE UNITS. PERMIT ARE REQUIRED FOR ALL ELECTRCIAL AND BUILDING REPAIRS. ALL UNITS ARE CONDEMNED. FOLLOW UP INSPECTION WITHIN 60 DAYS. ALL DOCUMENTS AND PHOTOS ARE IN SIRE.
01/15/2014 INSP - FOLLOW UP CODE ENFORCE PUMPHREY Approved Met owner at property; electric utility has been restored under repair permit T14CM00048, which is finaled. Case closed.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T13DV09467
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
12/30/2013 CONTACTED BY PHONE
12/30/2013 NOTICE AND ORDER ISSUED
12/30/2013 NOTICE OF VIOLATION ISSUED
01/22/2014 VIOLATION CLOSED
08/23/2014 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
12/30/2013 STRUCTURE SECURED BY ???
12/30/2013 CALLBACK

Documents

File Name Document Type  
PC100121.JPG DOCUMENTS VIEW
PC090105.JPG DOCUMENTS VIEW
PC090106.JPG DOCUMENTS VIEW
PC090107.JPG DOCUMENTS VIEW
PC090108.JPG DOCUMENTS VIEW
PC090109.JPG DOCUMENTS VIEW
PC090110.JPG DOCUMENTS VIEW
PC090111.JPG DOCUMENTS VIEW
PC090112.JPG DOCUMENTS VIEW
PC090113.JPG DOCUMENTS VIEW
PC090114.JPG DOCUMENTS VIEW
PC090115.JPG DOCUMENTS VIEW
PC090116.JPG DOCUMENTS VIEW
PC090117.JPG DOCUMENTS VIEW
PC090118.JPG DOCUMENTS VIEW
PC100119.JPG DOCUMENTS VIEW
PC100120.JPG DOCUMENTS VIEW
2511 N FONTANA.PDF DOCUMENTS VIEW