Case: T13DV08500
Case Details
Entered Date:
11/14/2013
Applicant:
JOSE F. MADA
Description:
EMERGENCY CALL/ HOUSE FIRE
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV08500
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 14
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2013 | NPO - UNSECURED BUILD OR STRUC | GOODMAN | Approved | |
| 11/14/2013 | NPO(DL)-VACANT & UNSEC.STRUCT | GOODMAN | Approved | |
| 11/14/2013 | NPO - INT. BUILDING MAINTENANC | GOODMAN | Approved | |
| 11/14/2013 | NPO - EXT. BUILDING MAINTENANC | GOODMAN | Approved | |
| 11/14/2013 | NPO(PL)-GAS SUPPLY/CONNECT | GOODMAN | Approved | |
| 11/14/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | GOODMAN | Approved | |
| 11/14/2013 | NPO(DL)-VACANT & UNSEC.STRUCT | GOODMAN | Approved | |
| 11/14/2013 | NPO - UNSECURED BUILD OR STRUC | GOODMAN | Approved | |
| 11/14/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | GOODMAN | Approved | |
| 11/14/2013 | NPO(PL)-GAS SUPPLY/CONNECT | GOODMAN | Approved | |
| 11/14/2013 | NPO - EXT. BUILDING MAINTENANC | GOODMAN | Approved | |
| 11/14/2013 | NPO - INT. BUILDING MAINTENANC | GOODMAN | Approved | |
| 11/14/2013 | INSP - INITIAL CODE ENFORCMENT | GGOODMAN | Approved | VISITED SITE, UPON ARRIVAL MET WITH TFD INVESTIGATORS AND TEP, BECAUSE OF THE CONNECTED STRUCTURES TEP MADE THE DECISION TO CUT THE POWER AT THE POLE INORDER TO ISOLATE THOSE BUILDINGS ALTOGETHER. SPOKE WITH S/W GAS, GAS HAD BEEN TURNED OFF SOME TIME AGO. TFD MENTIONED THE HOUSE IS VACANT AT THE TIME, OWNER MOVED OUT SEVERAL MONTHS AGO AND IS NOW LIVING WITH HIS SISTER. OWNER OF THE HOUSE IS ALSO THE OWNER OF CJ's BAR AND GRILLE. ADDRESS OF THE BAR WAS GIVEN AS 4581 S 12TH AVE. AND THE HOUSE AS 530 W OHIO. FOUND ELECTRICAL ISSUES AT THE MAIN SERVICE PANEL OF THE HOUSE. WAS ALLOWED TO WALK THE FRONT PORTION OF THE HOUSE, FIRE STARTED AT THE REAR ENCLOSED PATIO THAT JOINED THE HOUSE AND THE BAR. OWNER STATED THE ENCLOSED PATIO WAS BEING USED AS AN OFFICE / LIVING AREA. FINDINGS FOR THE HOUSE ARE AS FOLLOWS: > FOUND SEVERAL VIOLATIONS IN THE MAIN SERVICE PANEL , DBL & TRIPLE LUGGING, MISSING KNOCK OUTS, ADDED CIRCUITS, EXPOSED WIRING AND ILLEGAL SPLICES, POWER SHUT OFF TO THE STRUCTURE. > HEAVY SMOKE DAMAGE THRU OUT THE STRUCTURE >DAMAGED DRYWALL IN SEVERAL DIFFERENT PLACES >DAMAGE TO THE ROOF STRUCTURE, HOLE CUT IN THE ROOF BY TFD / CUT RAFTERS AND SHEaTHING TO CONVENTIONAL FRAME ROOF >HEAVY SMOKE DAMAGE TO BATH AND ELECTRICAL FIXTURES. >HEAVY SMOKE DAMAGE TO THE DUCT WORK. DAMAGE TO THE BAR IS AS FOLLOW: > REAR PATIO / ENCLOSER / ADDITION COMPLETELY FIRE DAMAGED, PLANS AND PERMITS WILL BE REQUIRED. >MAIN ELECTRICAL SEVICE PANEL WAS LOCATED IN THE ENCLOSED PATIO AND COMPLETELY FIRE DAMAGED. ELECTRICAL PANEL MAY NEED TO BE RELOCATED (NOT ACCESSIBLE) WIRING, OUTLETS, SWITCHES AND FIXTURES ALL FIRE DAMAGED. POWER SHUT OFF TO THE STRUCTURE. > PLUMBING LINES LOCATED IN THE ENCLOSED PATIO FIRE DAMAGED. BATHROOM AREA FIRE DAMAGED INCLUDING ALL FIXTURES. >INTERIOR OF THE BAR RECEIVED HEAVY SMOKE DAMAGE, |
| 06/10/2015 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | ALL REPAIRS BEING COMPLETED UNDER PERMIT T14CM03981. COMPLIANCE / CLOSE CASE. |
Completed Activity Special Conditions
Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T13DV08500
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 06/12/2015 | VIOLATION CLOSED |
| 05/29/2014 | SEC LETTER OF BILLING FOR $??? SENT TO OWNERS |