Case: T13DV07887
Case Details
Entered Date:
10/22/2013
Applicant:
MARIA LOPEZ
Description:
ELECTRICAL
Case Violations
Case Number: T13DV07887
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 10/22/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T13DV07887
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/12/2013 | NPO - UNSECURED BUILD OR STRUC | CBIGMAN | Item closed | |
| 12/12/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | CBIGMAN | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV07887
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2013 | INSP - INITIAL CODE ENFORCMENT | CBIGMAN | Approved | FRONT DOOR LOCKING MECHANISM APPEARS TO BE DEFECTIVE, AWNING ATTACHED TO MOBILE HOME IS MADE OUT OF 2 X 4'S. WASHING MACHINE CONNECTED WITH EXTENSION CORDS. |
| 12/09/2013 | INSP - FOLLOW UP CODE ENFORCE | CBIGMAN | Approved | ABATED CLOSE CASE |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV07887
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 10/23/2013 | CONTACTED BY MAILING |
| 10/23/2013 | NOTICE OF VIOLATION ISSUED |
| 12/12/2013 | VIOLATION CLOSED |
| 10/22/2013 | T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools. |
| 10/22/2013 | T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (6) Any portion of a building or structure, or any member, appurtenance or ornamentation on the exterior thereof is not of sufficient strength or stability, or is not so anchored, attached or fastened in place so as to be capable of resisting a wind pressure of one-half ( ½ ) of that specified in the building code for new buildings of similar structure, purpose or location without exceeding the working stresses permitted in the building code for such buildings. |