Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

10/14/2013

Applicant:

1050 EAST MOSSMAN LLC

Description:

Coakroaches, holes and cracks in the trailer. Broken windows.

Case Violations

Case Number: T13DV07658
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 8
Violation Date Code Statue
10/28/2013 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
10/28/2013 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
10/28/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
10/28/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
10/28/2013 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
10/28/2013 T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons.
10/28/2013 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
10/28/2013 T.C. Ch. 16, Sec. 16-12(d) COOLERS. Evaporative coolers, cooler stands, and any cooler mounting apparatus must be maintained in a safe condition. Cooler stands and any mounting apparatus must be structurally sound.

Outstanding Inspections

Case Number: T13DV07658
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
11/18/2013 NPO - UNSECURED BUILD OR STRUC WNAVARRO Follow-up inspection
11/18/2013 NPO - INSECTS/PESTS WNAVARRO Follow-up inspection
11/18/2013 NPO - EXT. BUILDING MAINTENANC WNAVARRO Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV07658
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/16/2013 INSP - INITIAL CODE ENFORCMENT WNAVARRO Approved Visited site, met tenant, inspected, found as folows,hot water heater is wired and poses a safety hazard, hallway ceiing was repaired with sheetrock and was not finished, ceiling in bedroom is deterriorated and poses a safety hazard, evaporitive cooler was installed and electrical was installed to electrical code,ceiling in living room is deterriorated, electrical in unit has open and exposed circuits, outlets are worn and does not hold appliance cords, loose outlets, no furnance,front and back door are out of adjustment and allowing exterior elements in unit, floor is deterriorated in several places,there are several windows that are broken, called owner and went thru the violations in unit, explained process of the notce of violation, time lines, extensions, inspection fees, citation process, will write notice of violation.
11/18/2013 INSP - FOLLOW UP CODE ENFORCE WNAVARRO Approved Visited site, inspected, tenant is moving, will follow up in thirty days

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T13DV07658
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
10/28/2013 CONTACTED BY MAILING
10/28/2013 NOTICE OF VIOLATION ISSUED
04/02/2014 VIOLATION CLOSED

Documents

File Name Document Type  
T13DV07658.PDF DOCUMENTS VIEW