Case: T13DV07222
Case Details
Entered Date:
09/25/2013
Applicant:
SILVIA PARADES CIFUENTES
Description:
WOP, STORAGE, HASP
Case Violations
Case Number: T13DV07222
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 09/25/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 09/25/2013 | T.C. Ch. 16, Sec. 16-11(a)(2) Every dwelling unit or guest room shall have unobstructed access directly to the outside, or to a public corridor. Every door, stairway, passageway or other means of exit shall be of sufficient size, width and arrangement so as to provide safe and rapid egress in the event of fire. Every walking surface of any means of exit shall be maintained free of warping, rotting, or other damage or obstructions so as to provide safe and rapid egress in the event of fire. |
| 09/25/2013 | T.C. Ch. 16, Sec. 16-12(f) ADDRESS DISPLAY. (1) General requirements: a. All structures, whether new or existing, designed for human occupancy or use which have an assigned address shall display the address in a manner to be plainly legible and visible from the street or road fronting the property. e. The complete address shall be displayed on all corner buildings at a street intersection, for each side of the building facing any street. f. Addresses shall be displayed and visible from both directions of approaching vehicular travel. g. Numbers and letters shall be made of durable and clearly visible material. Paint shall not be considered durable for building addresses. h. Numbers and letters shall be of colors contrasting with the background of the sign or wall to which they are attached. i. Numbers and letters shall have a minimum proportion ratio of height to width of six to one (6:1). The formula is w = h/6, where w is width and h is height in inches. j. Numbers shall not be spelled. k. All height requirements stated in this section are minimum sizes. |
| 09/25/2013 | T.C. Ch. 16, Sec. 16-12(e) ACCESSORY STRUCTURES. All accessory structures, including but not limited to detached garages, fences and walls, must be structurally sound and free of disrepair. Examples of disrepair include missing slats, posts or blocks, or damage, deterioration or rot. Fences and walls cannot be constructed or covered with materials not designed or commonly used for that purpose, such as pallets and tarps. Fences and walls must be properly anchored so as not to be in danger of failure or collapse. |
| 09/25/2013 | T.C. Ch. 16, Sec. 16-13(h) OUTDOOR STORAGE Outdoor storage on residential properties is prohibited under the following conditions: 1. When stored in the front yard. 2. When stored in the side yard or rear yard and is not screened by a minimum five foot high solid wall or opaque fence. 3. When exceeds 25% of the total lot area. 4. When stored in an open covered porch that is visible from beyond the boundaries of the lot. 5. When stored in an open carport that is visible from beyond the boundaries of the lot where the amount of storage restricts an automobile from being properly stored within the carport. A double carport will require enough space to store two automobiles. 6. When storage items include garbage, refuse or debris. |
Outstanding Inspections
Case Number: T13DV07222
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/19/2013 | LUC - RESIDENTIAL STORAGE | CBIGMAN | Item closed | |
| 11/19/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | CBIGMAN | Item closed | |
| 11/19/2013 | NPO(DL)-DILAPIDATED STRUCTURE | CBIGMAN | Item closed | |
| 11/19/2013 | NPO - EGRESS | CBIGMAN | Item closed | |
| 11/19/2013 | NPO - OTHER | CBIGMAN | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV07222
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2013 | INSP - INITIAL CODE ENFORCMENT | CBIGMAN | Approved | AWNING ATTACHED TO TRAILER CONSTRUCTED OF 2X2 BOARDS AND HAS 3 SUPPORT POST SCABBED TOGETHER HOLDING UP THE ROOFING OF THE AWNING. HEADER ATTACHED TO THE MOBILE HOME IS DETERIORATED. EXTERIOR LIGHT ELECTRICAL BOX ATTACHED TO THE MOBILE HOME HAS COVER PLATE MISSING. ZIP CORDS BEING USED AS PERMENANT WIRING, INTERIOR OUTLET BOX HAZAARDOUSLY ATTACHED/HANGING FROM THE EXTERIOR DISCONNECT BOX, NO 3 FT CLEARANCE AROUND ELECTRICAL DISCONNECT BOX, ADDRESS MISSING OFF MH, EXTERIOR STORAGE. |
| 11/13/2013 | INSP - FOLLOW UP CODE ENFORCE | CBIGMAN | Approved | CASE FULLY ABATED. CLOSE CASE. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T13DV07222
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 09/30/2013 | CONTACTED BY MAILING |
| 09/30/2013 | NOTICE OF VIOLATION ISSUED |
| 11/19/2013 | VIOLATION CLOSED |