Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

07/29/2013

Applicant:

BERJ & CELIA FUSTUKJIAN TR

Description:

Roof is caving in. Water leak. The front door is broken, and there is a rat and roach infestation.

Case Violations

Case Number: T13DV05448
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 4
Violation Date Code Statue
08/06/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
08/06/2013 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
08/06/2013 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.
08/06/2013 T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition.

Outstanding Inspections

Case Number: T13DV05448
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
08/01/2013 NPO(PL)-PLUMBING SYSTEM & FX JHURD Item closed
08/01/2013 NPO - INSECTS/PESTS JHURD Item closed
10/11/2013 NPO(EL)-MAIN/PANEL/SUB/DISCONT JHURD Item closed
10/11/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX JHURD Item closed
10/11/2013 NPO - EXT. BUILDING MAINTENANC JHURD Item closed
10/11/2013 NPO - INT. BUILDING MAINTENANC JHURD Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV05448
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/01/2013 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE: MET W/OCCUPANT: 1/2 THE APT IS WITH OUT ELECTRIC POWER. RUNNING EXTENSION CORD FROM NEIGHBOR FOR REFRIGERATOR. DISCONNECTED WHILE INSP. ON SITE. ELECT. CONTRACTOR TO BE OUT TODAY. 3 SEPERATE ENTRY/EXIT DOORS IN UNIT ALL LACK REQUIRED WEATHER STRIPPING. SOME LACK REQUIRED DOOR HARDWARE. N/O/V 30 DAYS. INTERIOR SUB-PANEL LACKS BREAKERS AND/OR COVER PLUGS ALLOWS ENTRY INTO SUB-PANEL. KITCHEN CEILING SHOWS ROOF LEAK, DAMAGE DRYWALL ON CEILING. CEILING FAN LACKS REQUIRED BASE COVER, OPEN ELECTRICAL CONNECTIONS. DIRTY, FULL OF DUST. KITCHEN LIGHT SWITCH COVER NOT LARGE ENOUGH TO COVER OUTLET BOX, OPEN ELECTRIC. KITCHEN FLOOR TILE MISSING IN AREAS. KITCHEN WINDOW BROKEN
10/07/2013 INSP - FOLLOW UP CODE ENFORCE JHURD Approved VISITED SITE: MET W/OWNER, UNIT REHABED. COMPLIANT @ THIS TIME. CLOSE/CASE.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T13DV05448
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
10/01/2013 CONTACTED BY PHONE
08/09/2013 CONTACTED BY MAILING
08/09/2013 NOTICE OF VIOLATION ISSUED
10/11/2013 VIOLATION CLOSED

Documents

File Name Document Type  
NOV T13DV05448 8-7-13.PDF DOCUMENTS VIEW