Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

07/22/2013

Applicant:

JOSE LUIS PAREDES & FELIX ESPERANZA JT/RS

Description:

COMMUNICATION CALLED THAT T.F.D. ON SITE WITH A HOUSE FIRE, ALARM # 132010160

Outstanding Inspections

Case Number: T13DV05247
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 10
End Date Description Inspector Results Comments
09/20/2013 NPO(EL)-MAIN/PANEL/SUB/DISCONT WNAVARRO Follow-up inspection
09/20/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX WNAVARRO Follow-up inspection
09/20/2013 NPO(PL)-PLUMBING SYSTEM & FX WNAVARRO Follow-up inspection
09/20/2013 NPO(PL)-WATER HEATERS WNAVARRO Follow-up inspection
09/20/2013 NPO(HC)-COOLING WNAVARRO Follow-up inspection
09/20/2013 NPO(HC)-HEATING & VENTILATION WNAVARRO Follow-up inspection
09/20/2013 NPO - SMOKE ALARMS WNAVARRO Follow-up inspection
09/20/2013 NPO - EXT. BUILDING MAINTENANC WNAVARRO Follow-up inspection
09/20/2013 NPO - WORK WITHOUT PERMIT WNAVARRO Follow-up inspection
09/20/2013 NPO - INT. BUILDING MAINTENANC WNAVARRO Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV05247
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/20/2013 INSP - INITIAL CODE ENFORCMENT RVIDAL Approved Received call from communication that T.F.D. on site with a house fire. Arrived and the units were cleaned up. Had a fire in the kitchen area over the stove in the attic. What burned was the wiring to the stove and oven, the hall bathroom and the bedrooms. The electrical meter was called in to have removed but the field crews were busy with down power lines. They were going to respond later in the evening or in the morning to have the electrical meter removed. Bathcrest was called to the property due not able to due a lock out due the locking device was missing. Bathcrest place metal screws on the door panel to secure the panel from having the breakers turned back on. The fire was in the attic and did burn parts of the wood trusses for the roof, the top plates for the back wall of the bathroom and insulation. Drywall was pulled down to check for fire in the ceiling and walls in the kitchen and the hall closet. The metal ductwork for the range hood was missing in the cabinet over the stove and in the attic the ductwork was loose with openings on the joints. Permit will be required for the electrical repairs or replacements and the reconnect for the electrical to be turned back on. The owner signed the paper work and will be staying at another location. The owners were talking to the insurance and gave the phone number to the Red Cross if needed for placement if not able to stay somewhere else for the night. Called communication that the electrical panel was screwed shut and to let the T.E.P. rep. know and leaving the site. Will check in 45 days. RV.
09/20/2013 INSP - FOLLOW UP CODE ENFORCE WNAVARRO Approved Visited site, inspected, unit still secured, left a business card, will reseach for permit

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T13DV05247
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
09/03/2013 NOTICE OF VIOLATION ISSUED
04/02/2014 VIOLATION CLOSED
04/11/2014 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
09/20/2013 RESEARCH
09/03/2013 CALLBACK

Documents

File Name Document Type  
None IMAGES VIEW