Case: T13DV05184
Case Details
Entered Date:
07/18/2013
Applicant:
ERICA COLBY # 18
Description:
UNIT # __: Exterior Inspection
Case Violations
Case Number: T13DV05184
Case Status: REFERRED
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
| Violation Date | Code Statue |
|---|---|
| 07/18/2013 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 07/18/2013 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. |
| 08/06/2013 | T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools. |
Outstanding Inspections
Case Number: T13DV05184
Case Status: REFERRED
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/29/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | LPUMPHRE | Item closed | |
| 10/29/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LPUMPHRE | Follow-up inspection | |
| 10/29/2013 | NPO(PL)-PLUMBING SYSTEM & FX | LPUMPHRE | Item closed | |
| 10/29/2013 | NPO(PL)-GAS SUPPLY/CONNECT | LPUMPHRE | Follow-up inspection | |
| 10/29/2013 | NPO(PL)-SEWAGE DISPOSAL (SYS) | LPUMPHRE | Item closed | |
| 10/29/2013 | NPO(PL)-WATER HEATERS | LPUMPHRE | Follow-up inspection | |
| 10/29/2013 | NPO - REFUSE/TRASH/DEBRIS | LPUMPHRE | Item closed |
Completed Inspections
Case Status: REFERRED
Case Number: T13DV05184
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/03/2013 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | Water heater has exposed conductors and exposed panel; water service lines appear undersized; gas line has no shutoff to unit; Hasp lock on front door; evap cooler has dilapidated stand, accumulation of refuse on property; front stairs are dilapidated with no rail or guards; electrical wiring to w/d through door not to adopted code and lacks permit; sewer is not to adopted code; main elec panel has loose outlet; fallen dead tree in yard. |
| 10/29/2013 | INSP - FOLLOW UP CODE ENFORCE | LPUMPHRE | Approved | Partial compliance; new owner Erica Colby 423-7624. Dilapidated porches still present; gas shutoff, and water heater installation. |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 08/06/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. | Not Approved |
| 08/06/2013 | T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. T.C. Ch. 6, IRC adopted. R311.4.3 LANDINGS AT DOORS. There shall be a floor or landing on each side of each exterior door. The floor or landing at the exterior door shall not be more than 1.5 inches (38mm) lower than the top of the threshold. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. T.C. Ch. 6, IRC adopted. R311.5.6 HANDRAILS. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. R311.5.6.1 Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). T.C. Ch. 6, IRC adopted. R312.1 GUARDS. Porches, balconies, ramps or raised floor surfaces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. R312.2 Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches (102mm) or more in diameter. | Not Approved |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05184
Case Status: REFERRED
Total Completed Case Activity Conditions: 2
| Date | Name |
| 07/18/2013 | NOTICE OF VIOLATION ISSUED |
| 03/27/2014 | VIOLATION CLOSED |