Case: T13DV05182
Case Details
Entered Date:
07/18/2013
Applicant:
MANUEL AGUAS
Description:
UNIT # 16: Exterior Inspection
Case Violations
Case Number: T13DV05182
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 2
| Violation Date | Code Statue |
|---|---|
| 07/18/2013 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 07/18/2013 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
Outstanding Inspections
Case Number: T13DV05182
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/02/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LPUMPHRE | Item closed | |
| 10/02/2013 | NPO(PL)-PLUMBING SYSTEM & FX | LPUMPHRE | Item closed | |
| 10/02/2013 | NPO(PL)-GAS SUPPLY/CONNECT | LPUMPHRE | Item closed | |
| 10/02/2013 | NPO(PL)-WATER HEATERS | LPUMPHRE | Item closed | |
| 10/02/2013 | NPO - WORK WITHOUT PERMIT | LPUMPHRE | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV05182
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/03/2013 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | Recent front porch and room addition and rear porch no permits; stairs no rails or guards (4 risers); gas has no shutoff to main; water heater not installed to code and lacks permit; washer/dryer on porch with added water & elec not to code and no permits; dryer lacks proper vent. |
| 10/01/2013 | INSP - FOLLOW UP CODE ENFORCE | LPUMPHRE | Approved | Compliant. |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 08/05/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. | Not Approved |
| 08/05/2013 | T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. T.C. Ch. 6, IRC adopted. R311.5.6 HANDRAILS. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. R311.5.6.1 Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). T.C. Ch. 6, IRC adopted. R312.1 GUARDS. Porches, balconies, ramps or raised floor surfaces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. R312.2 Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches (102mm) or more in diameter. | Not Approved |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05182
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 08/21/2013 | CONTACTED BY PHONE |
| 07/18/2013 | NOTICE OF VIOLATION ISSUED |
| 10/02/2013 | VIOLATION CLOSED |