Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T13DV05180
Case Details
Entered Date:
07/18/2013
Applicant:
FRANCISCO FRASQUILLO
Description:
UNIT # 13: Exterior Inspection
Case Violations
Case Number: T13DV05180
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 07/18/2013 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
Outstanding Inspections
Case Number: T13DV05180
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/08/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | LPUMPHRE | Item closed | |
| 10/08/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LPUMPHRE | Item closed | |
| 10/08/2013 | NPO - REFUSE/TRASH/DEBRIS | LPUMPHRE | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV05180
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/30/2013 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | Accumulation of refuse, broken window(s); porch addition is not to code; no landing or railings on steps; exterior outlet lacks faceplate and is not exterior rated or gfci; evap cooler elec connection is not to code. |
| 10/08/2013 | INSP - FOLLOW UP CODE ENFORCE | LPUMPHRE | Approved | Compliant. |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 08/05/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. | Not Approved |
| 08/05/2013 | T.C. Ch. 6, IRC adopted. R311.4.3 LANDINGS AT DOORS. There shall be a floor or landing on each side of each exterior door. The floor or landing at the exterior door shall not be more than 1.5 inches (38mm) lower than the top of the threshold. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. T.C. Ch. 6, IRC adopted. R311.5.6 HANDRAILS. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. R311.5.6.1 Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). | Not Approved |
| 08/05/2013 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. | Not Approved |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05180
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 07/18/2013 | NOTICE OF VIOLATION ISSUED |
| 11/04/2013 | VIOLATION CLOSED |