Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

REFERRED

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

07/18/2013

Applicant:

YOLANDA VEGA, UNIT # 12

Description:

UNIT # 12: Exterior Inspection

Case Violations

Case Number: T13DV05179
Case Status: REFERRED
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
Violation Date Code Statue
07/18/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
07/18/2013 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition.
07/31/2013 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.

Outstanding Inspections

Case Number: T13DV05179
Case Status: REFERRED
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
10/08/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX LPUMPHRE Follow-up inspection
10/08/2013 NPO(PL)-PLUMBING SYSTEM & FX LPUMPHRE Item closed
10/08/2013 NPO(PL)-GAS SUPPLY/CONNECT LPUMPHRE Follow-up inspection
10/08/2013 NPO - REFUSE/TRASH/DEBRIS LPUMPHRE Item closed
10/08/2013 NPO - EXT. BUILDING MAINTENANC LPUMPHRE Item closed

Completed Inspections

Case Status: REFERRED
Case Number: T13DV05179
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/30/2013 INSP - INITIAL CODE ENFORCMENT LPUMPHRE Approved Gas line no shutoff; broken windows; evap cooler installation is not to code and has x cord; sliding door has no stairs; wood window frame lacks paint; x cord threaded through window; outdoor washer has discharge into unit that is not to code; fascia lacks paint; refuse.
10/08/2013 INSP - FOLLOW UP CODE ENFORCE LPUMPHRE Approved Partial compliance; no gas shutoff installed, no gfci outlet for w/d.

Outstanding Case Activity Conditions

Date Name Approved
07/31/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. Not Approved
07/31/2013 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. Not Approved
07/31/2013 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. T.C. Ch. 6, IRC adopted. R311.4.3 LANDINGS AT DOORS. There shall be a floor or landing on each side of each exterior door. The floor or landing at the exterior door shall not be more than 1.5 inches (38mm) lower than the top of the threshold. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. T.C. Ch. 6, IRC adopted. R311.5.6 HANDRAILS. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. R311.5.6.1 Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). T.C. Ch. 6, IRC adopted. R312.1 GUARDS. Porches, balconies, ramps or raised floor surfaces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. R312.2 Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches (102mm) or more in diameter. Not Approved

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05179
Case Status: REFERRED
Total Completed Case Activity Conditions: 2
Date Name
07/18/2013 NOTICE OF VIOLATION ISSUED
03/25/2014 VIOLATION CLOSED