Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

07/18/2013

Applicant:

ANNA MARTINEZ, 1050 EAST MOSSMAN LLC

Description:

UNIT # 8: Exterior Inspection

Case Violations

Case Number: T13DV05175
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
Violation Date Code Statue
07/18/2013 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
07/18/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
07/18/2013 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition.
07/29/2013 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element.

Outstanding Inspections

Case Number: T13DV05175
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
10/08/2013 NPO(PL)-SEWAGE DISPOSAL (SYS) LPUMPHRE Follow-up inspection
10/08/2013 NPO(PL)-WATER HEATERS LPUMPHRE Follow-up inspection
10/08/2013 NPO - REFUSE/TRASH/DEBRIS LPUMPHRE Follow-up inspection
10/08/2013 NPO - EXT. BUILDING MAINTENANC LPUMPHRE Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV05175
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/30/2013 INSP - INITIAL CODE ENFORCMENT LPUMPHRE Approved Gas water heater is not installed to code, lacks cold water shutoff, incorrect tprv, lacks vent; sewer pipe not sealed correctly; backdoor is closed off with plywood, no stairs, preventing egress; accumulation of refuse; porch in front lacks rail and is not weather protected with paint; no access to elec.
10/08/2013 INSP - FOLLOW UP CODE ENFORCE LPUMPHRE Approved UNIT # 8: No compliance; property is vacant; NOV needs to be sent to owner at this point.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05175
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
04/10/2014 CONTACTED BY MAILING
07/18/2013 NOTICE OF VIOLATION ISSUED
04/04/2014 CITATION ISSUED
08/07/2014 VIOLATION CLOSED
04/10/2014 COURT HEARING INFO
07/29/2013 T.C. Ch. 6, IRC adopted. R312.1 GUARDS. Porches, balconies, ramps or raised floor surfaces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. R312.2 Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches (102mm) or more in diameter.

Documents

File Name Document Type  
6001 S PARK UNIT 8 - MARTINEZ.PDF DOCUMENTS VIEW
CITATION 6885187 T13DV05175.PDF DOCUMENTS VIEW