Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

07/18/2013

Applicant:

TINA HILL, JOHN K DALEY

Description:

UNIT # 6: Exterior Inspection

Case Violations

Case Number: T13DV05173
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
Violation Date Code Statue
07/18/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
07/18/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
07/26/2013 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.

Outstanding Inspections

Case Number: T13DV05173
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
10/08/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX LPUMPHRE Item closed
10/08/2013 NPO(PL)-PLUMBING SYSTEM & FX LPUMPHRE Item closed
10/08/2013 NPO(PL)-GAS SUPPLY/CONNECT LPUMPHRE Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV05173
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/28/2013 INSP - INITIAL CODE ENFORCMENT LPUMPHRE Approved Non exterior rated outlet with added wiring along fence is not installed to code; porch decking had dilapidated causing a trip hazard; gas service line has not shutoff to unit; water service line to unit is not of approved type or material (garden hose). staris for south door lack landing.
10/08/2013 INSP - FOLLOW UP CODE ENFORCE LPUMPHRE Approved

Outstanding Case Activity Conditions

Date Name Approved
07/26/2013 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. T.C. Ch. 6, IRC adopted. R311.4.3 LANDINGS AT DOORS. There shall be a floor or landing on each side of each exterior door. The floor or landing at the exterior door shall not be more than 1.5 inches (38mm) lower than the top of the threshold. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. Not Approved

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05173
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
07/18/2013 NOTICE OF VIOLATION ISSUED
11/04/2013 VIOLATION CLOSED