Case: T13DV05169
Case Details
Entered Date:
07/18/2013
Applicant:
JOSEFA AND MARIA MONTIJO
Description:
UNIT # 2: Exterior Inspection
Case Violations
Case Number: T13DV05169
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
| Violation Date | Code Statue |
|---|---|
| 07/18/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 07/18/2013 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 11/04/2013 | T.C. Ch. 6, IBC adopted. IBC 110.1 USE AND OCCUPANCY. No building or structure shall be used or occupied, and no change in the existing occupancy classification of a building or structure or portion thereof shall be made until the building official has issued a certificate of occupancy therefore as provided herein. |
Outstanding Inspections
Case Number: T13DV05169
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LPUMPHRE | Item closed | |
| 10/01/2013 | NPO(PL)-PLUMBING SYSTEM & FX | LPUMPHRE | Item closed | |
| 10/01/2013 | NPO(PL)-GAS SUPPLY/CONNECT | LPUMPHRE | Item closed | |
| 10/01/2013 | NPO(PL)-WATER HEATERS | LPUMPHRE | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV05169
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/28/2013 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | Exposed electrical splices at cooler and exterior yard light (owner verbally advised), gas meter no shutoff at trailer, no hand rail on front steps. Lifeline is spliced at main elec panel which also has improper ground and double lug. (panel repair is owner). |
| 10/01/2013 | INSP - FOLLOW UP CODE ENFORCE | LPUMPHRE | Approved | Compliant. |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 07/25/2013 | T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. T.C. Ch. 6, IRC adopted. R311.5.6 HANDRAILS. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. R311.5.6.1 Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). | Not Approved |
| 07/26/2013 | T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced. | Not Approved |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05169
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 08/14/2013 | CONTACTED BY PHONE |
| 07/18/2013 | NOTICE OF VIOLATION ISSUED |