Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

07/17/2013

Applicant:

RAMESH S PATEL & R KANCHAN, DBA RIVIERA MOTOR LODGE

Description:

UNIT # 19: Minimum housing inspection, Riviera Motel.

Case Violations

Case Number: T13DV05099
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
Violation Date Code Statue
07/17/2013 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
07/17/2013 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.
07/17/2013 T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools.
07/17/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
07/17/2013 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
07/17/2013 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T13DV05099
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
07/17/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX LPUMPHRE Notice of violation
07/17/2013 NPO - EGRESS LPUMPHRE Notice of violation
07/17/2013 NPO - SMOKE ALARMS LPUMPHRE Notice of violation
07/17/2013 NPO - INT. BUILDING MAINTENANC LPUMPHRE Notice of violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV05099
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/26/2013 INSP - INITIAL CODE ENFORCMENT LPUMPHRE Approved 2 wire ungrounded outlets; weatherstripping; rear door locked no key; one smoke detector in kitchen only; bed and bath have bars with no latch; front, kitchewindow broken latch; kitchen fixture needs bulb protection; wall added to create bedroom and living room without permit (can see wall on outside window.
06/03/2014 INSP - FOLLOW UP CODE ENFORCE PUMPHREY Approved Compliant.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05099
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
07/17/2013 NOTICE OF VIOLATION ISSUED
06/23/2014 VIOLATION CLOSED