Case: T13DV05097
Case Details
Entered Date:
07/17/2013
Applicant:
RAMESH S PATEL & R KANCHAN, DBA RIVIERA MOTOR LODGE
Description:
UNIT # 17: Minimum housing inspection, Riviera Motel.
Case Violations
Case Number: T13DV05097
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 07/17/2013 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
Outstanding Inspections
Case Number: T13DV05097
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/17/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LPUMPHRE | Notice of violation | |
| 07/17/2013 | NPO(HC)-HEATING & VENTILATION | LPUMPHRE | Notice of violation | |
| 07/17/2013 | NPO - SMOKE ALARMS | LPUMPHRE | Notice of violation | |
| 07/17/2013 | NPO - INT. BUILDING MAINTENANC | LPUMPHRE | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV05097
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2013 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | 2 wire ungrounded outlets; front door lacks weatherstripping; closet door missing knob; kitchen and bath fixture missing cover; no smoke detectors; kitchen window not latching; bathroom window missing crank; bedroom windows missing handles; door lacking striker plate; east bedroom has burn damage on outlet; door doesn't close well; walls patched; romex patched in drywall over door. |
| 06/03/2014 | INSP - FOLLOW UP CODE ENFORCE | PUMPHREY | Approved | Compliant. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05097
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 07/17/2013 | NOTICE OF VIOLATION ISSUED |
| 06/23/2014 | VIOLATION CLOSED |