Case: T13DV05095
Case Details
Entered Date:
07/17/2013
Applicant:
RAMESH S PATEL & R KANCHAN, DBA RIVIERA MOTOR LODGE
Description:
UNIT # 15: Minimum housing inspection, Riviera Motel.
Case Violations
Case Number: T13DV05095
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
| Violation Date | Code Statue |
|---|---|
| 07/17/2013 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
Outstanding Inspections
Case Number: T13DV05095
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/17/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LPUMPHRE | Notice of violation | |
| 07/17/2013 | NPO(HC)-HEATING & VENTILATION | LPUMPHRE | Notice of violation | |
| 07/17/2013 | NPO - SMOKE ALARMS | LPUMPHRE | Notice of violation | |
| 07/17/2013 | NPO - INT. BUILDING MAINTENANC | LPUMPHRE | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV05095
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2013 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | Front door lacks weatherstripping and striker; 2 wire ungrounded outlets; broken pane in kitchen and bath; crank broken in bedroom and bath; fixtures missing protection, one is hanging off wiring; closet and bath missing door knob; closet has vent pipe that is lacking a double wall on drywall; bathroom leaking at drain; no smoke detectors; broken cover plates; |
| 06/03/2014 | INSP - FOLLOW UP CODE ENFORCE | PUMPHREY | Approved | Compliant. |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(a)(2) Every dwelling unit or guest room shall have unobstructed access directly to the outside, or to a public corridor. Every door, stairway, passageway or other means of exit shall be of sufficient size, width and arrangement so as to provide safe and rapid egress in the event of fire. Every walking surface of any means of exit shall be maintained free of warping, rotting, or other damage or obstructions so as to provide safe and rapid egress in the event of fire. | Not Approved |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05095
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 07/17/2013 | NOTICE OF VIOLATION ISSUED |
| 06/23/2014 | VIOLATION CLOSED |