Case: T13DV05087
Case Details
Entered Date:
07/17/2013
Applicant:
RAMESH S PATEL & R KANCHAN, DBA RIVIERA MOTOR LODGE
Description:
UNIT # 4: Minimum housing inspection, Riviera Motel.
Case Violations
Case Number: T13DV05087
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
| Violation Date | Code Statue |
|---|---|
| 07/17/2013 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 07/17/2013 | T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
Outstanding Inspections
Case Number: T13DV05087
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/17/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LPUMPHRE | Notice of violation | |
| 07/17/2013 | NPO - SMOKE ALARMS | LPUMPHRE | Notice of violation | |
| 07/17/2013 | NPO - INT. BUILDING MAINTENANC | LPUMPHRE | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV05087
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2013 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | Door lacks weatherstripping; some windows missing handles, cranks, and are not working; broken panes; added outlets, 2 wire ungrounded outlets, no gfci in bath or kitchen; range hood has exposed romex; fixture missing globe; no smoke detectors; closet has unsupport gas line; bath sink cracked; exterior door dilapidated. |
| 02/06/2014 | INSP - FOLLOW UP CODE ENFORCE | PUMPHREY | Approved | Minimum housing inspection: passed as compliant. PDSD previously approved occupancy per an inspection 01/31/14 under permit T13CM04642; includes installation of mini-split and enclosure of rear door. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05087
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 07/17/2013 | NOTICE OF VIOLATION ISSUED |
| 02/06/2014 | VIOLATION CLOSED |