Unit # 2 : Minimum housing inspection, Riviera Motel.

Case Violations

Case Number: T13DV05049
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
07/16/2013 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
07/16/2013 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.
07/16/2013 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
07/16/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
07/17/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.

Outstanding Inspections

Case Number: T13DV05049
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
07/17/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX LPUMPHRE Notice of violation
07/17/2013 NPO(HC)-HEATING & VENTILATION LPUMPHRE Notice of violation
07/17/2013 NPO - EGRESS LPUMPHRE Notice of violation
07/17/2013 NPO - INT. BUILDING MAINTENANC LPUMPHRE Notice of violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV05049
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/26/2013 INSP - INITIAL CODE ENFORCMENT LPUMPHRE Approved Door lacks weatherstripping; cranks and handles missing on windows; broken panes; 2 wire ungrounded outlets; kitchen fixture missing cover; range hood elec not protected and circuit goes under sink; grounded refrig plugged into 2 wire outlet ; bath ceiling patched; walls peeling; door does not latch; rear door blocked with furniture; closet has gas line which is not suppported; kitchen switch loose.
02/06/2014 INSP - FOLLOW UP CODE ENFORCE PUMPHREY Approved Minimum housing inspection: passed as compliant. PDSD previously approved occupancy per an inspection 01/31/14 under permit T13CM04642; includes installation of mini-split and enclosure of rear door.

Outstanding Case Activity Conditions

Date Name Approved
07/17/2013 T.C. Ch. 16, Sec. 16-11(a)(2) Every dwelling unit or guest room shall have unobstructed access directly to the outside, or to a public corridor. Every door, stairway, passageway or other means of exit shall be of sufficient size, width and arrangement so as to provide safe and rapid egress in the event of fire. Every walking surface of any means of exit shall be maintained free of warping, rotting, or other damage or obstructions so as to provide safe and rapid egress in the event of fire. Not Approved

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T13DV05049
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
07/16/2013 NOTICE OF VIOLATION ISSUED
02/06/2014 VIOLATION CLOSED