Case: T13DV04780
Case Details
Entered Date:
07/09/2013
Applicant:
CITY NATIONAL BANK
Description:
Min Housing concerns
Case Violations
Case Number: T13DV04780
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
| Violation Date | Code Statue |
|---|---|
| 07/09/2013 | T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools. |
| 07/09/2013 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 07/09/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 07/09/2013 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
| 07/09/2013 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 07/09/2013 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 07/09/2013 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
Outstanding Inspections
Case Number: T13DV04780
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/01/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | MLOPEZ | Item closed | |
| 08/01/2013 | NPO(PL)-PLUMBING SYSTEM & FX | MLOPEZ | Item closed | |
| 08/01/2013 | NPO - SMOKE ALARMS | MLOPEZ | Item closed | |
| 08/01/2013 | NPO - EXT. BUILDING MAINTENANC | MLOPEZ | Item closed | |
| 08/01/2013 | NPO - INT. BUILDING MAINTENANC | MLOPEZ | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV04780
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2013 | INSP - INITIAL CODE ENFORCMENT | MLOPEZ | Approved | Found a few things wrong with the property, no smoke detector, weather strips bad on doors, and exterior violations. Will be issueing notice of violation to maintance man. follow up 07-26-2013 |
| 07/26/2013 | INSP - FOLLOW UP CODE ENFORCE | MLOPEZ | Approved | All violations at this unit have been abated, tenant very happy will be closing this case. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV04780
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 07/09/2013 | CONTACTED IN PERSON |
| 07/10/2013 | NOTICE OF VIOLATION ISSUED |
| 08/01/2013 | VIOLATION CLOSED |