Case: T13DV04668
Case Details
Entered Date:
07/05/2013
Applicant:
MARTHA E. HUBRED
Description:
House fire
Case Violations
Case Number: T13DV04668
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 07/08/2013 | T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration. |
| 07/08/2013 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 07/08/2013 | T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools. |
| 07/08/2013 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 07/08/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T13DV04668
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | AVINDIOL | Item closed | |
| 12/23/2013 | NPO(PL)-PLUMBING SYSTEM & FX | AVINDIOL | Item closed | |
| 12/23/2013 | NPO(PL)-GAS SUPPLY/CONNECT | AVINDIOL | Item closed | |
| 12/23/2013 | NPO - SMOKE ALARMS | AVINDIOL | Item closed | |
| 12/23/2013 | NPO - OTHER | AVINDIOL | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV04668
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/05/2013 | INSP - INITIAL CODE ENFORCMENT | AVINDIOL | Approved | 07/05/13 - ON SCENE FIRE CALL // GAS PINNED BY S/W GAS ELECTRICAL SHUT/LOCKED AT PANEL // FIRE STARTED SOME WHERE IN LIVING ROOM HEAT DAMAGE EVIDENT BY MELTED CONTENTS IN ROOM AND BLISTED TEXTURE AND PAINT OUTLET AND WIRES IN ROOM MUST HAVE SUFFERED THE SAME INSIDE WALL // SMOKE DAMAGE AND SOOT THROUGHOUT LIVING ROOM, KITCHEN HALLWAY AND 2 BEDROOMS / CEILING SHEETROCK DAMAGE IN LIVING ROOM / NO SMOKE DECTORS // FIRST BEDROOM WITH WROUGHT IRON OVER WINDOW WITH NO BREAK AWAY// SUB PANEL ( 60 AMP) IN BACK BEDROOM CIRCUITS CANNOT NOT BE IDENTIFIED // MAIN PANEL WAS NOT PROPERLY BONDED TO GROUND // LOOSE ROMEX OVERHANING CEILING IN SHED IN YARD // SHED BY BACK DOOR AND THROUGHOUT STRUCTURE ON THE EASTSIDE OF HOME // CONNECTIONS ON BENDS TO EXHAUST OVERWATER LACKS SCREWS // NOV TO FOLLOW // AV |
| 12/23/2013 | INSP - FOLLOW UP CODE ENFORCE | AVINDIOL | Approved | 12/23/13 FOLLOW UP TO FIND OWNERS SON IN LAW AT HOME // PERMIT WAS ISSUED AND REQUIRED ITEMS HAD BEEN FINALED UNDER # T13CM05714 // WILL MOVE TO CLOSE OUT THIS CASE // AV |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T13DV04668
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 10/21/2013 | CONTACTED BY PHONE |
| 07/08/2013 | CONTACTED IN PERSON |
| 07/08/2013 | NOTICE OF VIOLATION ISSUED |
| 12/23/2013 | VIOLATION CLOSED |