Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T13DV04663
Case Details
Entered Date:
07/03/2013
Applicant:
1050 EAST MOSSMAN LLC
Description:
MINIMAL HOUSING
Case Violations
Case Number: T13DV04663
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
| Violation Date | Code Statue |
|---|---|
| 07/03/2013 | UDC, Sec. 10.2.3. COMPLIANCE REVIEW, EXISTING DEVELOPMENT Any land used or occupied; any site improvement, modification, or construction started; any existing use or structure expanded, reconstructed, changed, or otherwise altered; and any land divided into multiple parcels without certification of compliance with the provisions of the UDC through a zoning review process is considered a violation of the UDC. Enforcement of violations shall be in accordance with Section 10.4, Penalties and Remedies. |
| 07/03/2013 | UDC, Sec. 10.3.5. VIOLATION OF A SITE PLAN Failure to comply with conditions placed on an approved site plan shall constitute a violation of the UDC. |
| 07/03/2013 | UDC, Sec. 10.3.4. VIOLATION OF CONDITIONS OF APPROVAL Failure to comply with the requirements or conditions of approval on any of the various zoning compliance procedures as provided by the UDC, such as, but not limited to, Special Exception, Design Development Option, Temporary Use, or Home Occupation procedures, constitutes a violation of the UDC. |
| 07/03/2013 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 07/03/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 07/03/2013 | T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition. |
| 07/03/2013 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. |
Outstanding Inspections
Case Number: T13DV04663
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2013 | LUC - VIOL OF SITE PLAN - COND | WNAVARRO | Notice of violation | |
| 11/14/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | WNAVARRO | Notice of violation | |
| 11/14/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | WNAVARRO | Notice of violation | |
| 11/14/2013 | NPO - REFUSE/TRASH/DEBRIS | WNAVARRO | Notice of violation | |
| 11/14/2013 | LUC - ZONING OTHER | WNAVARRO | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV04663
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2013 | INSP - INITIAL CODE ENFORCMENT | WNAVARRO | Approved | Visited site, inspected, found as follows, electrical service panel supplys units units twenty eight and twenty nine,porch was added, overspanned and pose a safety hazard due the structure members being undersized and overspanned, also electrical is a safety hazard due to supply line to addition is open and exposed to the outside elements, has a open junction box for clothes dryer connection, trash, debris in the rear of property, took pictures, will write notice of violation |
| 12/23/2013 | INSP - FOLLOW UP CODE ENFORCE | JVALDEZ | Approved | CONDUCTED SiTE INSPECTION PER SUPERVISOR ORDERS THE CARPORT / PORCH IS OVER 200 SQ FEET AND DILAPIDATED AND A PORTION OF IT IS ATTACHED TO THE MOBILE HOME. THE POSTS ARE A MIX OF 2 INCH STEEL PIPE AND DETERIORATED 4X4 POSTS. THE BEAMS ARE A MIX OF 2X4 LUMBER AND 4X4 LUMBER. THE WOOD 4X4 RAFTERS ARE SPANNED 10 FEET. OVER ALL THE CARPORT / PORCH MUST BE REMOVED. THE PROPERTY IS CLEAN. THE ELECTRICAL SYSTEM IS A PEDESTAL TYPE SYSTEM. THE UNIT HAS A LIFE RATED FOR ITS USE. THE BOTTOM COVER OF THE PEDESTAL HAS BEEN REMOVED THERE IS A CABLE CONNECT TO THE PEDESTALS TERMINALS WHICH RUNS OVER THE CHAIN LINK FENCE ALONG THE WOOD PANEL FENCE AND OVER AND ACROSS THE BACK YARD TO UNIT 27 PEDESTAL. THIS CONNECTION IN AN UNAPPROVED WIRING METHOD AND MUST BE DISCONNECT IMMEDIATELY. |
| 12/23/2013 | INSP - FOLLOW UP CODE ENFORCE | JVALDEZ | Approved | I RETURNED AND THE CONDITIONS OF THE POSTED NOTICE WERE COMPLETED AND ABATED. FOLLOW UP INSPECTION DUE 1-24-2014 |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV04663
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
| Date | Name |
| 12/30/2013 | CONTACTED BY PHONE |
| 12/30/2013 | CONTACTED IN PERSON |
| 08/22/2013 | CONTACTED BY MAILING |
| 12/30/2013 | NOTICE AND ORDER ISSUED |
| 08/22/2013 | NOTICE OF VIOLATION ISSUED |
| 02/03/2014 | VIOLATION CLOSED |
| 11/19/2013 | REINSPECTION FEE - FIRST |