Case Violations
Case Number: T13DV04652
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 9
| Violation Date | Code Statue |
|---|---|
| 07/03/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 07/03/2013 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 07/03/2013 | T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition. |
| 07/03/2013 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. |
| 08/16/2013 | T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools. |
| 08/16/2013 | T.C. Ch. 16, Sec. 16-13(a) ACCUMULATION OF VEGETATION PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of the accumulation or untended growth of vegetation. The accumulation or untended growth of vegetation means the presence of plants on property that create a fire, safety or health hazard, or that attract vermin either on the property, on neighboring properties, or on both, and includes but is not limited to: (1) Any lawn grass that exceeds 6 inches in height; (2) All weeds that exceed 6 inches in height; (3) Dead trees and dead shrubs; (4) Dead palm fronds within ten feet of the ground, a structure, a fence or wall, or of any combustible other than the tree from which the fronds have grown; (5) Any tree, shrub, or other form of vegetation of any kind on the property or on the adjoining right-of-way, street, or alley that extends over or under the sidewalk space or roadway in a manner that may interfere with the reasonable use of the street, sidewalk, or alley for pedestrian or vehicular traffic of any kind or that may obstruct the view or light distribution of traffic-control devices or luminaries. Vegetation must be trimmed and maintained to provide an unobstructed pedestrian path a minimum 48 inches in width and 80 inches in height from grade. |
| 08/16/2013 | UDC, Sec. 10.2.3. COMPLIANCE REVIEW, EXISTING DEVELOPMENT Any land used or occupied; any site improvement, modification, or construction started; any existing use or structure expanded, reconstructed, changed, or otherwise altered; and any land divided into multiple parcels without certification of compliance with the provisions of the UDC through a zoning review process is considered a violation of the UDC. Enforcement of violations shall be in accordance with Section 10.4, Penalties and Remedies. |
| 08/16/2013 | UDC, Sec. 10.3.5. VIOLATION OF A SITE PLAN Failure to comply with conditions placed on an approved site plan shall constitute a violation of the UDC. |
| 08/16/2013 | UDC, Sec. 10.3.4. VIOLATION OF CONDITIONS OF APPROVAL Failure to comply with the requirements or conditions of approval on any of the various zoning compliance procedures as provided by the UDC, such as, but not limited to, Special Exception, Design Development Option, Temporary Use, or Home Occupation procedures, constitutes a violation of the UDC. |
Outstanding Inspections
Case Number: T13DV04652
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/18/2013 | LUC - VIOL OF SITE PLAN - COND | WNAVARRO | Item closed | |
| 11/18/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | WNAVARRO | Item closed | |
| 11/18/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | WNAVARRO | Item closed | |
| 11/18/2013 | NPO(PL)-PLUMBING SYSTEM & FX | WNAVARRO | Item closed | |
| 11/18/2013 | NPO - REFUSE/TRASH/DEBRIS | WNAVARRO | Item closed | |
| 11/18/2013 | NPO - WEEDS/GRASSES | WNAVARRO | Item closed | |
| 11/18/2013 | LUC - ZONING OTHER | WNAVARRO | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV04652
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2013 | INSP - INITIAL CODE ENFORCMENT | WNAVARRO | Approved | Visited site, inspected,found as follows,windows are blocked for egress,gas main line connection has no shut off valve,there is an addition that is not to code,two romex wirs are supplying cooler and are hazardous,, water heater encloserure is deterriorated, no shut off vale for the gas line |
| 11/18/2013 | INSP - FOLLOW UP CODE ENFORCE | WNAVARRO | Approved | Visited site, inspected, found property in compliance, case closed abated |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV04652
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 08/22/2013 | CONTACTED BY MAILING |
| 08/22/2013 | NOTICE OF VIOLATION ISSUED |