Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

06/27/2013

Applicant:

DONALD WAYNE SHOEMAKER

Description:

NO RUNNING WATER/PLUMBING/ NO EVAP AC- DUE TO NO WATER

Case Violations

Case Number: T13DV04459
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 8
Violation Date Code Statue
06/28/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
06/28/2013 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
06/28/2013 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability.
06/28/2013 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
06/28/2013 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
06/28/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
06/28/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (4) All plumbing fixtures shall be connected to a public sewer system or to an approved private sewage disposal system, with the connections free from leaks, blockages, or other defects. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water necessary for its normal operation.
06/28/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (5) When a structure is equipped with a gas supply system, it must be installed and maintained in a safe, hazard-free condition.

Outstanding Inspections

Case Number: T13DV04459
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
08/26/2013 NPO(EL)-MAIN/PANEL/SUB/DISCONT CBIGMAN Item closed
08/26/2013 NPO(PL)-PLUMBING SYSTEM & FX CBIGMAN Item closed
08/26/2013 NPO(PL)-GAS SUPPLY/CONNECT CBIGMAN Item closed
08/26/2013 NPO(HC)-HEATING & VENTILATION CBIGMAN Item closed
08/26/2013 NPO - SMOKE ALARMS CBIGMAN Item closed
10/28/2013 NPO - WORK WITHOUT PERMIT JHURD Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV04459
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/27/2013 INSP - INITIAL CODE ENFORCMENT CBIGMAN Approved WATER SHUT OFF INSIDE UNIT DUE TO REPAIR TO LAVATORY. TOILET TANK REMOVED COMPLETELY, SINK COMPLETELY REMOVED. NO SMOKE DETECTORS IN UNIT, 2 WIRE SYSTEM CHANGED TO 3 WIRE SYSTEM. OUTLETS NOT GROUNDED. EXTERIOR LIGHT GLOBE MISSING, ADDED ELECTRICAL, BACK WINDOW CEMENTED IN. WATER HEATER HAS NO TPRV VALVE OR COLD WATER SHUTOFF. VENT REGISTERS MISSING THROUGHOUT THE UNIT, BACK PATIO ENCLOSED TO MAKE A LAUNDRY RM, PROTECTIVE LIGHT GLOBE IN KITCHEN MISSING OVER COOKING AREA.
10/28/2013 INSP - FOLLOW UP CODE ENFORCE JHURD Approved Permit in active status, T13CM04262. Expires 1/11/2014.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T13DV04459
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
08/30/2013 CONTACTED BY PHONE
07/09/2013 CONTACTED BY MAILING
07/10/2013 RED CROSS / PRIMAVERA
07/09/2013 NOTICE OF VIOLATION ISSUED
07/10/2013 8-5 CITY COMM EMERGENCY