Case: T13DV04342
Case Details
Entered Date:
06/24/2013
Applicant:
GRACE W & SAMUEL H YOUNG CP/RS
Description:
POOL- ELECTRICAL TO POOL LIGHT MODIFIED WITHOUT PERMIT. POOL KEY UNDER COUCH CUSHION ON PORCH OF #54
Case Violations
Case Number: T13DV04342
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-COMMERCL
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 06/27/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T13DV04342
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-COMMERCL
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2013 | NPO - WORK WITHOUT PERMIT | AVINDIOL | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV04342
Case Description: WORK WITHOUT PERMITS-COMMERCL
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2013 | INSP - INITIAL CODE ENFORCMENT | AVINDIOL | Approved | 06/26/13 - INITIAL INSPECTION - MET WITH MAINT MAN SHOWED US TO POOL AREA STATES POOL PUMP WAS WORKED ON // THEN SHOWED US TO PANEL FOR POOL // DOUBLE LUGGING AND ROMEX WIRING OUT OF PANEL TO OUTLET NOT RATED FOR EXTERIOR // OUTLET IN THAT WAS WIRED FOR TIMER ALSO NOT EXTERIOR OUTLET TYPE ALSO WILL NEED TO BE CHANGED // NUMBERS EXCHANGED AND NUMBER TO MANAGER TOO // WILL FOLLOW UP // AV |
| 07/23/2013 | INSP - FOLLOW UP CODE ENFORCE | AVINDIOL | Approved | 07/23/13 - FOLLOW UP WITH MAINT MAN JORGE // ROMEX COVERED IN CONDUIT // OUTLET NOW OUTDOOR TYPE AND DOUBLE LUGGINE ELIMINATED // WILL MOVE TO CLOSE OUT // AV |
Completed Activity Special Conditions
Case Description - WORK WITHOUT PERMITS-COMMERCL
Case Number - T13DV04342
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 06/27/2013 | CONTACTED BY PHONE |
| 06/27/2013 | CONTACTED IN PERSON |
| 06/28/2013 | CONTACTED BY MAILING |
| 06/27/2013 | NOTICE OF VIOLATION ISSUED |
| 07/23/2013 | VIOLATION CLOSED |