Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES
Address:

Entered Date:

06/10/2013

Applicant:

FOOTHILLS MHP LLC ATTN: 45-46-47 FOOTHILLS LOTS

Description:

MULT

Case Violations

Case Number: T13DV03989
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 3
Violation Date Code Statue
06/10/2013 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
06/10/2013 T.C. Ch. 16, Sec. 16-12(b)(2) WALLS. Exterior walls shall be maintained in a sound condition that is substantially weathertight and weatherproof, and shall be protected from the elements by paint or other approved protective covering. Exterior walls must be free of loose, crumbling or deteriorated plaster or rotted, split or buckled exterior wall coverings.
06/10/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T13DV03989
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
07/30/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX JHURD Item closed
07/30/2013 NPO(PL)-WATER HEATERS JHURD Item closed
07/30/2013 NPO - EXT. BUILDING MAINTENANC JHURD Item closed
07/30/2013 NPO - WORK WITHOUT PERMIT JHURD Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV03989
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/04/2013 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE: HOUSE 1: HOT WATER TANK ROOM: USING 3/8 COPPER LINE TO SUPPLY HOT AND COLD WATER TO INTERIOR. DRYWALL MISSING FROM WALLS, CEILING, OPENINGS INTO LIVING SPACE. OPEN ELECTRICAL, WALLS, CEILING. LICENSE CONTRACTOR TO EVULATE COMBUSTABLE AIR FOR HOT WATER HEATER. N/O/V 30 DAYS.
07/30/2013 INSP - FOLLOW UP CODE ENFORCE JHURD Approved VISITED SITE: PROPERTY COMPLIANT @ THIS TIME. CLOSE/CASE.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T13DV03989
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
07/30/2013 NOTICE OF VIOLATION ISSUED
09/16/2013 VIOLATION CLOSED