Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING

Entered Date:

04/30/2013

Applicant:

JULIE E. SIERRA

Description:

COMMUNICATION CALLED THAT T.F.D. ON SITE WITH A HOUSE FIRE

Case Violations

Case Number: T13DV02823
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Violations: 2
Violation Date Code Statue
05/01/2013 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
05/01/2013 T.C. Ch. 16, Sec. 16-14. Dilapidated structures; vacant and unsecured structures; buildings and structures constituting a nuisance. (a) Dilapidated structures. Buildings or structures that are so deteriorated, damaged, dilapidated, or in need of repair so as to present a threat to the health, safety and welfare of the community constitute a nuisance and shall be abated by repair, rehabilitation or demolition as provided in Article VI of this chapter.

Outstanding Inspections

Case Number: T13DV02823
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 10
End Date Description Inspector Results Comments
08/16/2013 NPO(EL)-MAIN/PANEL/SUB/DISCONT JVALDEZ Extension granted
08/16/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX JVALDEZ Extension granted
08/16/2013 NPO(PL)-PLUMBING SYSTEM & FX JVALDEZ Extension granted
08/16/2013 NPO(PL)-GAS SUPPLY/CONNECT JVALDEZ Extension granted
08/16/2013 NPO(PL)-WATER HEATERS JVALDEZ Extension granted
08/16/2013 NPO(HC)-COOLING JVALDEZ Extension granted
08/16/2013 NPO(HC)-HEATING & VENTILATION JVALDEZ Extension granted
08/16/2013 NPO - SMOKE ALARMS JVALDEZ Extension granted
08/16/2013 NPO - EXT. BUILDING MAINTENANC JVALDEZ Extension granted
08/16/2013 NPO - INT. BUILDING MAINTENANC JVALDEZ Extension granted

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV02823
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/30/2013 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved EMERGENCY CALL OUT BY TFD; THIS IS ONE BUILDING WITH 5 APARTMENT UNITS. CONSTRUCTION TYPE IS SLUMP BLOCK. UNIT 1 SUSTAINED THE MOST DAMAGE. THE WEST SIDE OF THE UNITS WALL WOOD MEMBERS TO INCLUDE THE BEAM, RAFTERS, ROOF SHEATHING HAVE DEEP CRACKS AND ARE BURNT. THERE IS EXPOSED AND BARE BURNT WIRING IN THE LIVING AND KITCHEN AREA. SEVERE SMOKE DAMAGE IN THE INTERIOR. THIS UNIT ALSO HAS AN ATTACHED 6 X 16 PORCH WHICH ALL THE WOOD MEMBERS ARE SEVERELY DAMAGE WITH DEEP CRACKS AND SOME MEMBERS ARE CHARRED. THERE IS BARE WIRING IN THIS AREA. TEP DID PULL ALL 5 METERS AND CUT THE SERVICE DROP. SWG DID REMOVE ALL THERE EQUIPMENT FROM THE PROPERTY, THEY EXPOSE THERE SERVICE LINE AND PLUGGED IT. THE UNIT WAS CONDEMNED DUE TO FIRE DAMAGE. A PLACARD WAS POSTED ON THE FRONT OF THE BUILDING WHICH READ UNSAFE TO OCCUPY. PHOTOS AND DOCUMENTS ARE IN SIRE. FOLLOW UP IN 60 DAYS
08/16/2013 INSP - FOLLOW UP CODE ENFORCE JVALDEZ Approved PERMIT T13CM02863 ISSUED FOR PARTIAL DEMO FOR ASSESSMENT FROM FIRE DAMAGE/ PARTIAL INSPECTION PASSED ON 6-25-2013 PERMIT T13CM03439 IN ISSUED STATUS FOR FIRE DAMAGE REPAIR - LIKE FOR LIKE R1- ON PLUMBING AND ADD UNITS 2-5 PERMIT EXPIRES ON 02/01/2014

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T13DV02823
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 8
Date Name
04/30/2013 CONTACTED BY PHONE
04/30/2013 CONTACTED IN PERSON
05/02/2013 CONTACTED BY MAILING
04/30/2013 NOTICE AND ORDER ISSUED
02/26/2014 VIOLATION CLOSED
03/18/2014 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
04/30/2013 STRUCTURE SECURED BY ???
04/30/2013 CALLBACK

Documents

File Name Document Type  
308 W IRVINGTON RD UNIT1.PDF DOCUMENTS VIEW
308 W IRVINGTON RD UNIT 1.PDF DOCUMENTS VIEW
P4100001.JPG DOCUMENTS VIEW
P4100002.JPG DOCUMENTS VIEW
P4110003.JPG DOCUMENTS VIEW
P4110004.JPG DOCUMENTS VIEW
P4110005.JPG DOCUMENTS VIEW
P4110006.JPG DOCUMENTS VIEW
P4110007.JPG DOCUMENTS VIEW
P4110008.JPG DOCUMENTS VIEW
P4110009.JPG DOCUMENTS VIEW
P4110010.JPG DOCUMENTS VIEW
P4110011.JPG DOCUMENTS VIEW
P4110012.JPG DOCUMENTS VIEW
P4110013.JPG DOCUMENTS VIEW
P4110014.JPG DOCUMENTS VIEW
P4110015.JPG DOCUMENTS VIEW
P4110016.JPG DOCUMENTS VIEW
P4110017.JPG DOCUMENTS VIEW
P4110018.JPG DOCUMENTS VIEW
P4110019.JPG DOCUMENTS VIEW
P4110020.JPG DOCUMENTS VIEW
P4110021.JPG DOCUMENTS VIEW