Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T13DV02514
Case Details
Entered Date:
04/18/2013
Applicant:
CHEYENNE RASMUSSEN
Description:
1/3 of house does not have electricity, no smoke alarms in the house, gate to back yard not closing and pool in back yard.
Case Violations
Case Number: T13DV02514
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 6
Violation Date | Code Statue |
---|---|
04/23/2013 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
04/23/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
04/23/2013 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
04/23/2013 | T.C. Ch. 16, Sec. 16-12(e) ACCESSORY STRUCTURES. All accessory structures, including but not limited to detached garages, fences and walls, must be structurally sound and free of disrepair. Examples of disrepair include missing slats, posts or blocks, or damage, deterioration or rot. Fences and walls cannot be constructed or covered with materials not designed or commonly used for that purpose, such as pallets and tarps. Fences and walls must be properly anchored so as not to be in danger of failure or collapse. |
04/23/2013 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. |
04/23/2013 | T.C. Ch. 16, SEC. 16-21. REGISTRATION OF RESIDENTIAL RENTAL PROPERTY. An owner of residential rental property shall maintain with the assessor in the county where the property is located information required by this section in a manner to be determined by the assessor. (c) Residential rental property shall not be occupied if the information required by this section is not on file with the county assessor. This subsection does not affect any lease existing on August 6, 1999. (e) A person who fails to comply with any provision of this subsection is responsible for a civil infraction and shall be assessed a civil penalty of one thousand dollars ($1,000.00), plus an additional one hundred dollars ($100.00) for each month after the date of the original violation until compliance occurs. The court shall not suspend any portion of the civil penalty provided by this subsection. |
Outstanding Inspections
Case Number: T13DV02514
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 12
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/12/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | MENDOZA | Item closed | |
11/12/2013 | NPO(PL)-PLUMBING SYSTEM & FX | MENDOZA | Item closed | |
11/12/2013 | NPO(DL)-DILAPIDATED STRUCTURE | MENDOZA | Follow-up inspection | |
11/12/2013 | NPO(DL)-VACANT & UNSEC.STRUCT | MENDOZA | Item closed | |
11/12/2013 | NPO - SMOKE ALARMS | MENDOZA | Item closed | |
11/12/2013 | NPO - GRAFFITI | RMENDOZA | Item closed | |
11/12/2013 | NPO - REFUSE/TRASH/DEBRIS | MENDOZA | Follow-up inspection | |
11/12/2013 | NPO - WEEDS/GRASSES | RMENDOZA | Item closed | |
11/12/2013 | NPO - EXT. BUILDING MAINTENANC | MENDOZA | Item closed | |
11/12/2013 | NPO - WORK WITHOUT PERMIT | MENDOZA | Follow-up inspection | |
11/12/2013 | NPO - INT. BUILDING MAINTENANC | MENDOZA | Item closed | |
11/12/2013 | NPO - REGISTER RENTAL PROPERTY | MENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV02514
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/18/2013 | INSP - INITIAL CODE ENFORCMENT | CBIGMAN | Approved | PROPERTY INSPECTION: NO WORKING SMOKE DETECTORS, VERY DEEP AND LARGE POOL IN BACK YARD FRONT GATE COMPLETELY REMOVED OFF WALL. EXTERIOR PERIMETER WALL ON THE SOUTH SIDE OF THE PROPERTY HAS STRUCTURAL DAMAGE, 2 PRONG SYSTEM USING 3 PRONG OUTLETS THROUGHT HSE, ADDED ROOM: ON WEST SIDE OF KITCHEN, LAUNDRY RM, MSTR BDRM EXTENDED, BACK UTILITY RM ADDED, NOT COMPLETED, WATER HEATER DOOR MISSING, FLUE PIPE/FIRE STOP NOT PROPERLY ATTACHED, GRAFITTI ON EXTERIOR WALL, LIGHT GLOBES MISSING ON INTERIOR LIGHT FIXTURES, DRY WALL NO COMPLETED, REFUSE SCATTERED AROUND EXTERIOR PROPERTY, TALL GRASS AND WEEDS. (WELL ON SITE?). RENTAL PROPERTY LISTED AS OWNER OCCUPIED. NO WEATHER STRIPPING AROUND FRONT DOOR |
11/12/2013 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | Most trash removed. Junked motor vehicle removed. No fee at this time. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T13DV02514
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 9
Date | Name |
04/19/2013 | CONTACTED BY PHONE |
04/19/2013 | CONTACTED IN PERSON |
05/09/2013 | CONTACTED BY MAILING |
05/09/2013 | NOTICE OF VIOLATION ISSUED |
05/15/2014 | CITATION ISSUED |
05/15/2014 | COURT HEARING INFO |
09/06/2013 | RESEARCH |
03/10/2015 | REFERENCE |
06/28/2013 | REINSPECTION FEE - FIRST |