Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING
Address:

Entered Date:

03/11/2013

Applicant:

PIMATUC REALTY ASSOCIATES

Description:

APT FIRE

Outstanding Inspections

Case Number: T13DV01382
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
09/30/2013 NPO(EL)-MAIN/PANEL/SUB/DISCONT AVINDIOL Item closed
09/30/2013 NPO(PL)-GAS SUPPLY/CONNECT AVINDIOL Item closed
09/30/2013 NPO - EXT. BUILDING MAINTENANC AVINDIOL Item closed
09/30/2013 NPO - WORK WITHOUT PERMIT AVINDIOL Item closed
09/30/2013 NPO - INT. BUILDING MAINTENANC AVINDIOL Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV01382
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
03/10/2013 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved MANAGER: ECHO CASNAVE (623-595-4793) TENANTS: KETAHIA DOUK (652-370-2566) MAINTANENCE SUPERVISOR:KEN SIEBERT (203-4156) VISITED SITE, MET WITH TFD INVESTIGATORS AND S/W GAS TECHNICIAN. POWER HAD BEEN TURNED OFF BY TFD/TEP AND GAS SHUT OFF BY S/W GAS TO THE ENTIRE BUILDING (16 UNITS) DUE TO FIRE IN UNIT #248. FIRE STARTED ON THE REAR SECOND STORY PORCH AND ENTERED THE INTERIOR OF THE LIVINGROOM AREA. FIRE AND SMOKE DAMAGE TO THE ONE BEDROOM UNIT WAS SIGNIFICANT AND REQUIRED A EMERGENCY SHUT DOWN: >REAR PORCH ROOF SHEATHING, 2X6 RAFTERS, FACIA AND BEARING 2X10, AND RAILINGS WERE ALL FIRE DAMAGED BEYOND REPAIR. > INTERIOR CEILING DRYWALL AND REAR BEARING WALL DRYWALL WERE ALSO FIRE DAMAGED AND PARTIALLY REMOVED FROM THE WALL AND CEILING. >TOP CORDS OF (3) TRUSSES WERE FIRE DAMAGED ALONG WITH TRUSS BLOCKING AND ROOF SHEATING 4 FT UP FROM REAR BEARING WALL. LARGE 3X8 HOLE CUT IN ROOF BY TFD. >ELECTRICAL WIRING INSIDE THE CEILING AREA WAS ALSO FIRE DAMAGED ALONG WITH OUTLETS AND FIXTURES. WIRING LEFT EXPOSED. >GAS WAS SHUT OFF TO THE COMPLEX BUT FED ONLY THE STOVE TOP (ONLY GAS APPLIANCE). GAS WAS LEFT OFF TO THE COMPLEX UNITS DID HAVE MICROWAVES FOR COOKING. INSPECTION FOUND EACH UNIT HAD A SUB PANEL IN EACH BATHROOM. POWER WAS SHUT OFF TO THE MAIN SERVICE PANEL BY TFD AND THEN TEP SHUT DOWN THE MAIN DISCONNECT. POWER TO UNIT # 248 WAS ISOLATED AT THE INTERIOR SUB PANEL AND WITH THE HELP OF MAINTANENCE SUPERVISOR KEN SIEBERT, POWER WAS RESTORED TO EACH UNIT ONE BY ONE CHECKING UNITS AS WE WENT. TENANTS WERE ALLOWED TO ENTER UNIT TO BEGIN REMOVING BELONGINGS AND WILL BE BUT UP IN UNIT #138 BY MANAGEMENT. BATHCREST WAS CALLED TO SECURE SLIDING GLASS DOOR ON THE BALCONY (PER MANAGEMENT) TO HELP SECURE PERSONAL BELONGINGS.
09/27/2013 INSP - FOLLOW UP CODE ENFORCE AVINDIOL Approved 09/27/13 ON SITE AGAIN MET WITH MANANGER OF PROPERTY AND MAINT MAN // ALL WAS COMPLETED AND PERMIT T13CM03104 ALL FINALED // WILL MOVE TO CLOSE OUT THIS CASE // AV

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T13DV01382
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
03/11/2013 NOTICE AND ORDER ISSUED
03/11/2013 NOTICE OF VIOLATION ISSUED
09/27/2013 VIOLATION CLOSED
01/02/2014 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS

Documents

File Name Document Type  
2929 E 6TH ST_EMERGENCY DOCUMENTS.PDF DOCUMENTS VIEW