Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE
Address:

Entered Date:

02/28/2013

Applicant:

MARY ANN ALLSTRAM

Description:

Guest house at rear porch caught on fire; Alarm #F130590092.

Case Violations

Case Number: T13DV01174
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Violations: 2
Violation Date Code Statue
03/01/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
03/01/2013 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.

Outstanding Inspections

Case Number: T13DV01174
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
04/12/2013 NPO(DL)-DILAPIDATED STRUCTURE CBIGMAN Item closed
04/12/2013 NPO - EXT. BUILDING MAINTENANC CBIGMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV01174
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/28/2013 INSP - INITIAL CODE ENFORCMENT CBIGMAN Approved PORCH ON RENTAL UNIT LOCATED BEHIND HOUSE CAUGHT FIRE. CHAIR ON PORCH BURNED AND SOME WOOD BURNED. STRUCTUAL INTEGRITY OF THE PORCH IS STILL INTACT AND WAS NOT COMPROMISED. A FEW PLANKS WILL NEED TO BE REPLACED AND PART OF THE RAILING WILL NEED TO BE REPLACED. NO PERMITS REQUIRED FOR THE REPAIR. ELECTRICAL JUNCTION BOX UNDER THE PORCH NEEDS A COVER AND CONDUIT NEEDS TO BE PLACED ON ELECTRICAL WIRING NEXT TO THE DOOR ON THE UNIT. EXPLAINED THIS TO THE OWNER AND LET HER KNOW, I'D FOLLOW UP IN 30 DAYS.
04/05/2013 INSP - FOLLOW UP CODE ENFORCE CBIGMAN Approved burned wood replaced junction box has covere, conduit added. case abated.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T13DV01174
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
03/01/2013 CONTACTED IN PERSON
03/04/2013 NOTICE OF VIOLATION ISSUED
04/12/2013 VIOLATION CLOSED
02/28/2013 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
7830 ADAMSNOV.PDF DOCUMENTS VIEW
None IMAGES VIEW