Case: T13DV01107
Case Details
Entered Date:
02/26/2013
Applicant:
JOHN W. & CAROL S. CROUSE TR
Description:
No heat. Roof is leaking.
Case Violations
Case Number: T13DV01107
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
| Violation Date | Code Statue |
|---|---|
| 02/28/2013 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
| 02/28/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 02/28/2013 | T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition. |
| 02/28/2013 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 02/28/2013 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
| 03/19/2013 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
Outstanding Inspections
Case Number: T13DV01107
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/18/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | ESTEVENS | Item closed | |
| 06/18/2013 | NPO(PL)-PLUMBING SYSTEM & FX | ESTEVENS | Item closed | |
| 06/18/2013 | NPO(HC)-HEATING & VENTILATION | ESTEVENS | Item closed | |
| 06/18/2013 | NPO(DL)-DILAPIDATED STRUCTURE | ESTEVENS | Item closed | |
| 06/18/2013 | NPO - WORK WITHOUT PERMIT | ESTEVENS | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV01107
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/26/2013 | INSP - INITIAL CODE ENFORCMENT | ESTEVENS | Approved | At site, spoke to tenant and owner. Heating unit on roof, turns on and stays hot for about 10 minutes, gets cold but fan kept running blowing cold air. Roof leaks in several places, water stains on ceiling. Leaks in kitchen, living room, both bedrooms and front porch. Flooring in the kitchen is peeling up. Flooring in the living room has soft spots, week sub-floor, near the sofa and tv. Water heater is not enclosed, no shut off valve. Water faucet out by the street leaks. Bathroom faucet leaks. Electrical outlet in kitchen not secured to the box. Kitchen lighting fixture about the sink is faulty. F/U 30 days. |
| 06/18/2013 | INSP - FOLLOW UP CODE ENFORCE | ESTEVENS | Approved | Researched P+, issue abated, permit final. Close case. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV01107
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 04/03/2013 | CONTACTED BY PHONE |
| 03/01/2013 | CONTACTED BY MAILING |
| 03/01/2013 | NOTICE OF VIOLATION ISSUED |
| 06/24/2013 | VIOLATION CLOSED |
| 06/18/2013 | RESEARCH |
| 03/19/2013 | 8-5 CITY COMM EMERGENCY |