Case: T13DV01073
Case Details
Entered Date:
02/22/2013
Applicant:
MISSION CREEK 1 LLC
Description:
Stairwell is falling apart near apt 2119
Case Violations
Case Number: T13DV01073
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
Violation Date | Code Statue |
---|---|
02/26/2013 | T.C. Ch. 6, IRC adopted. R311.5.3.1 RISER HEIGHT. The maximum riser height shall be 7 3/4 inches (196 mm). The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm).T.C. Ch. 6, IRC adopted. R311.7.5.1 RISER HEIGHT. The maximum riser height shall be 7 ¾ inches (196 mm). The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). Risers shall be vertical or sloped from the underside of the nosing of the tread above at an angle not more than 30 degrees from the vertical. Open risers are permitted provided that the opening between treads does not permit the passage of a 4-inch diameter sphere. |
Outstanding Inspections
Case Number: T13DV01073
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/05/2013 | NPO - EXT. BUILDING MAINTENANC | ESTEVENS | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV01073
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/25/2013 | INSP - INITIAL CODE ENFORCMENT | ESTEVENS | Approved | At site, spoke to manager Tomi. She stated that all the steps painted yellow are on the list to be repaired or replaced. F/U 30 days. |
04/05/2013 | INSP - FOLLOW UP CODE ENFORCE | ESTEVENS | Approved | At site, spoke to manager, Tomi. Step has been replace. Close case. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV01073
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
02/26/2013 | CONTACTED BY MAILING |
02/26/2013 | NOTICE OF VIOLATION ISSUED |
04/05/2013 | VIOLATION CLOSED |