Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

02/11/2013

Applicant:

BASHARAT & NIGHAT MAHMOOD JT/RS

Description:

Hole underneath the sink. Windows are not sealed properly. The locks on the door do not lock. Sinks plugged. Also an RV is hooked up to the apartment and using electricity without his permission.

Case Violations

Case Number: T13DV00856
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 6
Violation Date Code Statue
02/13/2013 T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools.
02/13/2013 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
02/13/2013 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.
02/13/2013 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
02/13/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
02/13/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.

Outstanding Inspections

Case Number: T13DV00856
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 8
End Date Description Inspector Results Comments
06/18/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX ESTEVENS No violation
06/18/2013 NPO(PL)-PLUMBING SYSTEM & FX ESTEVENS No violation
06/18/2013 NPO(HC)-COOLING ESTEVENS No violation
06/18/2013 NPO(DL)-DILAPIDATED STRUCTURE ESTEVENS No violation
06/18/2013 NPO - SMOKE ALARMS ESTEVENS No violation
06/18/2013 NPO - OTHER ESTEVENS No violation
06/18/2013 NPO - EXT. BUILDING MAINTENANC ESTEVENS No violation
06/18/2013 NPO - INT. BUILDING MAINTENANC ESTEVENS No violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV00856
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/12/2013 INSP - INITIAL CODE ENFORCMENT ESTEVENS Approved At site, found RV parked in the back with water and electrical hooked up. Sewage pipe leaking wasted water on ground. Spoke to owner of RV, Mr. Clark, explained violations and removed water hose and electrical cord. Refuse of mattresses and sofa frame on the side of complex. More refuse behind unit #14 and around trailer. UNIT #14 Cooler has exposed electrical wires Back door is an interior door without a doorknob or dead bolt lock. Front security door has no working doorknob ans screen is cut. Front door has a broken door jam and door will not lock. hole in cabinet near kitchen sink, allowing entrance for bugs and rodent. Front bedroom window will not open. Front bedroom door will not close properly. Back bedroom window will not lock. Cabinet door not installed properly. No hot water. UNIT # 11 Front door knob will not lock. Water leaks above stove. Water pipe behind kitchen cabinets leaks. Toilet backs up into bath tub. UNIT #2 Doors not secured. refuse behind unit #2 and around dumpster. overgrown vegetation in front of unit.
06/19/2013 INSP - FOLLOW UP CODE ENFORCE ESTEVENS Approved At site, all issues on occupied uints have been repaired. Violations on vacant units have not been repaired and these unit have been posted with Keep Vacant Notices. Close case.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T13DV00856
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
03/25/2013 CONTACTED BY MAILING
03/28/2013 CERTIFIED RECEIPT CARD
03/25/2013 NOTICE OF VIOLATION ISSUED
06/24/2013 VIOLATION CLOSED
03/25/2013 REINSPECTION FEE - FIRST

Documents

File Name Document Type  
3521 N FLOWING WELLS NOV.PDF DOCUMENTS VIEW
REGULAR MAILED NOV.PDF DOCUMENTS VIEW