Case: T13DV00377
Case Details
Entered Date:
01/16/2013
Applicant:
DON LEREW HOMES
Description:
RMIN: Trailer #7 has holes in the floor/ceiling vents do not close/no insulation to keep heat in/windows not properly insulated and rain leaks inside. Reported issues to Owner's son, Tom.
Case Violations
Case Number: T13DV00377
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
| Violation Date | Code Statue |
|---|---|
| 01/28/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 01/28/2013 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 01/28/2013 | T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
Outstanding Inspections
Case Number: T13DV00377
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/24/2013 | NPO - EXT. BUILDING MAINTENANC | ESTEVENS | Item closed | |
| 03/05/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | ESTEVENS | Item closed | |
| 03/05/2013 | NPO(DL)-DILAPIDATED STRUCTURE | ESTEVENS | Item closed | |
| 03/05/2013 | NPO - INT. BUILDING MAINTENANC | ESTEVENS | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV00377
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/24/2013 | INSP - INITIAL CODE ENFORCMENT | ESTEVENS | Approved | At site with tenant. Front bedroom has a hole in the floor, electrical outlet boxes are not secured to wall. Middle bedroom outlets not secured to wall. Behind front door there is a soft spot in the floor. Roofing materials curling up on the North side of trailer. |
| 03/05/2013 | INSP - FOLLOW UP CODE ENFORCE | ESTEVENS | Approved | At site, issues abated, close case. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV00377
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 01/29/2013 | CONTACTED BY MAILING |
| 01/29/2013 | NOTICE OF VIOLATION ISSUED |
| 03/07/2013 | VIOLATION CLOSED |