Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T12DV11330
Case Details
Entered Date:
12/28/2012
Applicant:
6142 E 22ND STREET LLC ATTN: JEREMY SOHN
Description:
FIRE CALL
Outstanding Inspections
Case Number: T12DV11330
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2012 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | JVALDEZ | Item initialized | |
| 12/28/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JVALDEZ | Item initialized | |
| 12/28/2012 | NPO(PL)-PLUMBING SYSTEM & FX | JVALDEZ | Item initialized | |
| 12/28/2012 | NPO(DL)-DILAPIDATED STRUCTURE | JVALDEZ | Item initialized |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV11330
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2012 | INSP - INITIAL CODE ENFORCMENT | JVALDEZ | Approved | EMERGENCY CALL OUT BY TFD: THERE WAS FIRE DAMAGE TO OVER 50% OF THE ROOF STRUCTURE DEEP CRACKS IN THE RIDGE BEAM, RAFTERS AND THE ROOF PLANKING. THERE ARE 3 ROOF AREAS THAT WERE CUT OUT BY TFD THE CUT OUTS ARE 4 FEET BY 4 FEET. THERE IS A 10 X 28 FOOT ADDITION AT THE REAR OF THE MAIN BUILDING THAT HAS FIRE DAMAGE AT THE WINDOW AND EXIT DOOR OPENINGS. THE INTERIOR OF THE BUILDING HAS BARE WIRING AND EXPOSED NON METALLIC SHEATHED CABLE. TEP DID REMOVE THE METER AND CUT THE SERVICE DROP. SWG DID PIN THE METER OFF IN THE ALLEY. THE INTERIOR DRYWALL IS DAMAGED. PERMITS REQUIRED FOR ALL REPAIRS SCHEDULE A FOLLOW INSPECTION FOR 60 DAYS |
| 07/08/2013 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | Business now re-opened. Permit approved 5/22/13. |
Completed Activity Special Conditions
Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T12DV11330
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 12/28/2012 | CONTACTED IN PERSON |
| 12/28/2012 | NOTICE AND ORDER ISSUED |
| 01/02/2013 | NOTICE OF VIOLATION ISSUED |
| 07/11/2013 | VIOLATION CLOSED |
| 02/13/2013 | RESEARCH |
| 12/28/2012 | CALLBACK |