Case: T12DV10841
Case Details
Entered Date:
12/03/2012
Applicant:
WILKINS FAMILY TR, ATTN: ATTN: PHILIP C & VICKI L WILKINS
Description:
Water heater and gas lines improperly installed. Roach infestation.
Case Violations
Case Number: T12DV10841
Case Status: COURTCMP
Case Description: MULTIPLE TYPES
Total Violations: 4
| Violation Date | Code Statue |
|---|---|
| 12/10/2012 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
| 12/10/2012 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 12/10/2012 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 12/11/2012 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (5) When a structure is equipped with a gas supply system, it must be installed and maintained in a safe, hazard-free condition. |
Outstanding Inspections
Case Number: T12DV10841
Case Status: COURTCMP
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2012 | NPO(PL)-PLUMBING SYSTEM & FX | LPUMPHRE | Notice of violation | |
| 12/10/2012 | NPO(PL)-GAS SUPPLY/CONNECT | LPUMPHRE | Notice of violation | |
| 12/10/2012 | NPO(HC)-HEATING & VENTILATION | LPUMPHRE | Item initialized |
Completed Inspections
Case Status: COURTCMP
Case Number: T12DV10841
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2012 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | No heating to unit. Tenants are currently using space heaters. Water supply piping appears to be ½ pex tubing throughout unit, on exterior of walls, with no support or protection through cutouts. Water heaters on west side appears installed under permit. Existing interior gas supply pipe capped off, likely supplied a furnance, but is now running under bathroom door and not supported. |
| 12/06/2013 | INSP - FOLLOW UP CODE ENFORCE | LPUMPHRE | Approved | Research. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T12DV10841
Case Status: COURTCMP
Total Completed Case Activity Conditions: 9
| Date | Name |
| 12/03/2012 | CONTACTED BY PHONE |
| 12/10/2012 | CONTACTED IN PERSON |
| 04/24/2013 | CONTACTED BY MAILING |
| 04/29/2013 | CERTIFIED RECEIPT CARD |
| 12/10/2012 | NOTICE OF VIOLATION ISSUED |
| 04/16/2013 | CITATION ISSUED |
| 01/28/2014 | VIOLATION CLOSED |
| 04/24/2013 | COURT HEARING INFO |
| 01/16/2013 | RESEARCH |