Case: T12DV09929
Case Details
Entered Date:
10/23/2012
Applicant:
DANIEL PITA
Description:
Chemical smells from apt ...landlord will let in Inspector
Case Violations
Case Number: T12DV09929
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 2
| Violation Date | Code Statue |
|---|---|
| 10/25/2012 | T.C. Ch. 16, Sec. 16-11(b) (3) VENTILATION. b. Bathrooms, laundry rooms, water closet compartments and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than 1 ½ square feet. A mechanical ventilation system connected directly to the outside may be provided in lieu of these required exterior openings for natural ventilation in bathrooms that contain a bathtub, shower or combination thereof; laundry rooms; and similar rooms. Such a system must be capable of providing 5 air changes at the rate of 50 cubic feet per minute if the system operation is intermittent; or 20 cubic feet per minute if the operation is constant. The point of discharge of exhaust air shall be at least 3 feet from any opening into the building. In bathrooms containing only a water closet, lavatory or combination thereof; or in similar rooms, ventilation may be provided with an approved mechanical recirculating fan or a similar device designed to remove odors from the room. |
| 10/25/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T12DV09929
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/23/2012 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | Furnace/water heater closet is full of storage. Exposed/added wiring in the same closet. |
| 11/15/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Item closed | |
| 11/15/2012 | NPO - INT. BUILDING MAINTENANC | RMENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV09929
Case Description: EMERGENCY
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/15/2012 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | Items removed from the furnace closet. Exposed electrical removed. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T12DV09929
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 10/25/2012 | CONTACTED IN PERSON |
| 10/26/2012 | CONTACTED BY MAILING |
| 10/26/2012 | NOTICE OF VIOLATION ISSUED |
| 11/15/2012 | VIOLATION CLOSED |