Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

10/23/2012

Applicant:

DANIEL PITA

Description:

Chemical smells from apt ...landlord will let in Inspector

Case Violations

Case Number: T12DV09929
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 2
Violation Date Code Statue
10/25/2012 T.C. Ch. 16, Sec. 16-11(b) (3) VENTILATION. b. Bathrooms, laundry rooms, water closet compartments and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than 1 ½ square feet. A mechanical ventilation system connected directly to the outside may be provided in lieu of these required exterior openings for natural ventilation in bathrooms that contain a bathtub, shower or combination thereof; laundry rooms; and similar rooms. Such a system must be capable of providing 5 air changes at the rate of 50 cubic feet per minute if the system operation is intermittent; or 20 cubic feet per minute if the operation is constant. The point of discharge of exhaust air shall be at least 3 feet from any opening into the building. In bathrooms containing only a water closet, lavatory or combination thereof; or in similar rooms, ventilation may be provided with an approved mechanical recirculating fan or a similar device designed to remove odors from the room.
10/25/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T12DV09929
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
10/23/2012 INSP - INITIAL CODE ENFORCMENT RMENDOZA Approved Furnace/water heater closet is full of storage. Exposed/added wiring in the same closet.
11/15/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX RMENDOZA Item closed
11/15/2012 NPO - INT. BUILDING MAINTENANC RMENDOZA Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV09929
Case Description: EMERGENCY
Total Completed Inspections - 1
End Date Description Inspector Results Comments
11/15/2012 INSP - FOLLOW UP CODE ENFORCE RMENDOZA Approved Items removed from the furnace closet. Exposed electrical removed.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T12DV09929
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
10/25/2012 CONTACTED IN PERSON
10/26/2012 CONTACTED BY MAILING
10/26/2012 NOTICE OF VIOLATION ISSUED
11/15/2012 VIOLATION CLOSED

Documents

File Name Document Type  
1603NBELVEDERENOV1.PDF DOCUMENTS VIEW