Electrical wiring problems,

Case Violations

Case Number: T12DV07319
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 3
Violation Date Code Statue
08/22/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
08/22/2012 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
08/22/2012 T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools.

Outstanding Inspections

Case Number: T12DV07319
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
12/12/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX JHURD Follow-up inspection 1st ReInspection Fee Applied
12/12/2012 NPO - EGRESS JHURD Follow-up inspection 1st ReInspection Fee Applied
12/12/2012 NPO - EXT. BUILDING MAINTENANC JHURD Follow-up inspection 1st ReInspection Fee Applied
12/12/2012 NPO - WORK WITHOUT PERMIT JHURD Follow-up inspection 1st ReInspection Fee Applied

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV07319
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/20/2012 INSP - INITIAL CODE ENFORCMENT JHURD Approved EMERGENCY CALL OUT: T.P.D T.P.D ON SITE: ELECTRICAL ISSUES, LIVING COND. EXTERIOR ELECTRICAL ISSUES, DATA LINES NO ISSUE, NO HAZARDS. OWNERS UNIT: ALL CONVENIENCE OUTLETS, LIGHT SWITCHES MISSING PROTECTIVE COVERS. BATHROOM: BATHROOM HEATER REMOVED, OPEN EXPOSED ELECTRICAL WIRES. DE-ENERGIZED. KITCHEN: W.O.P_ KITCHEN HAS BEEN SPLIT IN HALF BY ADDED WALL. LACKS REQUIRED CONVENIENCE OUTLETS, LIGHT. EXTENSION CORDS SUPPLYING SERVICE TO REFRIGERATOR, MICRO WAVE, TOASTER OVEN AND FLOURESENT LIGHT HANGING FROM CEILING ALL FROM 1 15 AMP CIRCUIT. OPPOSITE SIDE TURNED INTO BEDROOM. NO EGRESS. ONLY EGRESS FROM DWELLING IS FRONT DOOR. CAN NOT GET TO REAR DOOR. ITEMS BLOCKING. N/O/V 30 DAYS.
12/12/2012 INSP - FOLLOW UP CODE ENFORCE JHURD Approved RESEARCH: P.P. SHOWS NO SECURE PERMIT AS REQUIRED. 75.00 REINSPECTION FEE ACCESSED TO PROPERTY. FOLLOW UP 30 DAYS.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T12DV07319
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
08/29/2012 CONTACTED BY MAILING
08/29/2012 NOTICE OF VIOLATION ISSUED
08/20/2013 VIOLATION CLOSED
12/12/2012 RESEARCH
12/13/2012 REINSPECTION FEE - FIRST

Documents

File Name Document Type  
NOV T12DV07319.PDF DOCUMENTS VIEW