Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

08/17/2012

Applicant:

JAMES SANCHEZ

Description:

Due to recent storms the fencing has become dilapidated and temporarily wired together by occupant and her daughter. Gas company refused to turn on gas due to furnace being vented through fresh air return. Hot water heater installed in the kitchen and not vented properly. Roof leaks through spare bedroom ceiling and walls when it rains. Garage floods when it rains. Main electrical panel is overloaded.

Case Violations

Case Number: T12DV07238
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
Violation Date Code Statue
09/05/2012 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
09/05/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
09/05/2012 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
09/05/2012 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.
09/05/2012 T.C. Ch. 16, Sec. 16-13(g)(3) HAZARDOUS POOLS. Any swimming pool or other contained body of water that contains water 18 inches or more in depth at any point and that is wider than 4 feet at any point and is intended for swimming must be properly secured and maintained so as not to create a hazard to public safety, a health hazard or attractive nuisance, and shall be entirely enclosed by a wall, fence or other barrier that is adequate to prevent access by children. Water shall not be allowed to stagnate or to harbor insect infestation.
09/05/2012 T.C. Ch. 16, SEC. 16-21. REGISTRATION OF RESIDENTIAL RENTAL PROPERTY. An owner of residential rental property shall maintain with the assessor in the county where the property is located information required by this section in a manner to be determined by the assessor. (c) Residential rental property shall not be occupied if the information required by this section is not on file with the county assessor. This subsection does not affect any lease existing on August 6, 1999. (e) A person who fails to comply with any provision of this subsection is responsible for a civil infraction and shall be assessed a civil penalty of one thousand dollars ($1,000.00), plus an additional one hundred dollars ($100.00) for each month after the date of the original violation until compliance occurs. The court shall not suspend any portion of the civil penalty provided by this subsection.

Outstanding Inspections

Case Number: T12DV07238
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 7
End Date Description Inspector Results Comments
12/06/2012 NPO(EL)-MAIN/PANEL/SUB/DISCONT CBIGMAN Follow-up inspection
12/06/2012 NPO(PL)-GAS SUPPLY/CONNECT CBIGMAN Follow-up inspection
12/06/2012 NPO(PL)-WATER HEATERS CBIGMAN Follow-up inspection
12/06/2012 NPO(DL)-DILAPIDATED STRUCTURE CBIGMAN Follow-up inspection
12/06/2012 NPO - EXT. BUILDING MAINTENANC CBIGMAN Follow-up inspection
12/06/2012 NPO - WORK WITHOUT PERMIT CBIGMAN Follow-up inspection
12/06/2012 NPO - INT. BUILDING MAINTENANC CBIGMAN Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV07238
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/17/2012 INSP - INITIAL CODE ENFORCMENT CBIGMAN Approved MET W/OCCUPANT (WHO PLANS ON MOVING OUT NEXT WEEK). FOUND DBL LUGGING AT DISCONNECT BOX, PROPERTY NOT LISTED AS A RENTAL UNIT, ROOF LEAKING WATER, WATER HEATER HAS GAS PIPING CORRUGATED TUBING APPEARS TO BE TWISTED, VENTING ON FURNANCE NEED TO REMOVE TAPE ON THE COLD AIR RETURN, ELECTRICAL WIRES FOR THE POOL PUMP ARE NOT WEATHER PROTECTED. OCCUPANT COMPLAINED ABOUT POOL FENCE, WHEN I WENT TO THE SITE THE FENCE HAD BEEN REPAIRED WITH BOARDS BY THE OCCUPANT. CK VENTING ISSUE W/J.H. THE CONFIGURATION OF THE VENTING FOR THE WATER HEATER IS OK.
12/06/2012 INSP - FOLLOW UP CODE ENFORCE CBIGMAN Approved NO PERMITS PULLED FOR THE PROPERTY. RESEND NOV TO OWNER AND CHARGE HIM $75.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T12DV07238
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 8
Date Name
10/03/2012 CONTACTED BY PHONE
09/06/2012 CONTACTED BY MAILING
09/06/2012 NOTICE OF VIOLATION ISSUED
01/25/2013 CITATION ISSUED
11/02/2016 VIOLATION CLOSED
01/25/2013 COURT HEARING INFO
01/31/2013 CHANGE OF ADDRESS
12/07/2012 REINSPECTION FEE - FIRST

Documents

File Name Document Type  
None IMAGES VIEW
9069 BERKSHIRECIT.PDF DOCUMENTS VIEW
9069 BERKSHIRENOV.PDF DOCUMENTS VIEW