Case: T12DV06374
Case Details
Entered Date:
07/31/2012
Applicant:
COMMUNITY PARTNERSHIP HOUSING LLC
Description:
AIR CONDITIONING IS BROKEN
Outstanding Inspections
Case Number: T12DV06374
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/07/2012 | NPO(HC)-COOLING | GGOODMAN | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV06374
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/02/2012 | INSP - INITIAL CODE ENFORCMENT | GGOODMAN | Approved | VISITED SITE, KNOCKED ON OFFICE DOOR, RECEIVED NO ANSWER, AND OFFICE DOOR WAS LOCKED. WENT TO THE FAMILY HOUSING CENTER NEXT DOOR 8050 E LAKESIDE PW, PERSON MENTIONED THE RESPONSIBLE PERSON WAS SONIA (272-1821). WALKED BACK TO THE AREA IN QUESTION SPOKE WITH A PASSER BY, WHO MENTIONED THE PEOPLE IN QUAD 1101- 1104 WERE THE PEOPLE IN QUESTION, A/C UNIT HAS BEEN WORKING OFF AND ON FOR APPROX. 2 WEEKS. CALLED SONIA, LEFT MESSAGE. CHECKED ELECTRICAL BREAKER BOX FOR 1101-1104, FOUND CIRCUIT BREAKERS FOR THE A/C REMAINED ON. IT WAS WARM BUT NOT UNBEARABLE INSIDE. ** DROVE TO 535 N WILMOT TO SPEAK WITH OWNERS (ON BASE PAGE) FOUND OWNER WERE NO LONGER THERE, HAD MOVED TO SOMEWHERE ON BROADWAY. ** RECEIVED CALL BACK FROM SONIA WITH NICALOSI AND FITCH, SONIA MENTIONED IT HAS BEEN AN ONGOING PROBLEM BECAUSE OCCUPANTS CONTINUALLY LEAVE THE DOORS OPEN IN THE ROOMS AS WELL AS THE FRONT DOOR OF THE QUAD. AIR MAINTANENCE/FRANK (449-2431) WAS CALLED OUT LAST WEEK AND MADE REPAIRS. THEY WERE CALLED OUT AGAIN ON 8/01 FOUND UNITS COILS WERE FROZEN OVER, UNIT TAKEN APART AND WAITING FOR AIR MAINTANENCE TO GO BACK OUT. ** CONTACTED FRANK AT AIR MAINTANENCE APPROX. 3:30 PM, FRANK WAS PRESENTLY ONSITE, CONFIRMED HE WAS OUT IN THE AM TOOK APART THE UNIT TO ALLOW PARTS TO DE-THAW, HAS NOT YET DIAGNOSED THE PROBLEM BUT COULD CALL BACK. ** RECEIVED CALL BACK FROM AIR MAINTANENCE, FRANK MENTIONED A/C UNIT DID HAVE A BAD EXPANTION VALVE, WOULD BE ORDERED IN THE AM, SHIPPED OVERNIGHT FROM ALABAMA LENNOX DEALER AND REPLACED SAME DAY IT IS RECEIVED. ** RECEIVED CALL FROM SONIA APPROX. 7 PM MENTIONED, SHE HAD RECEIVED SAME INFO FROM FRANK. SONIA FIRST SPOKE WITH SUPERVISION AND WAS ADVISED TO GIVE EACH OCCUPANT THE OPTION OF RECEIVING A FAN OR MOVING TEMPORARILY TO ANOTHER EMPTY UNIT WITHIN THE AREA. EMPTY UNITS AND FANS ARE TO FANS ARE BE LOCATED AND OCCUPANTS GEVEN THE OPTION. ** WILL FOLLOW UP ON MONDAY 8/6/2012 DUE TO BEING OUT ON 8/3 AND KNOWING WORK IS IN PROGRESS. |
08/07/2012 | INSP - FOLLOW UP CODE ENFORCE | GGOODMAN | Approved | REVISITED SITE, FOUND A/C UNITS OPERATING PROPERLY. SPOKE WITH TENANT WHO MENTIONED UNIT WAS REPAIRED ON FRIDAY 8/03 AS STATED. NOV NOT REQUIRED DUE TO WORK IN PROGRESS. COMPLIANCE / CLOSE CASE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T12DV06374
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date | Name |
08/16/2012 | VIOLATION CLOSED |