Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

07/30/2012

Applicant:

STEVEN D. & KRISTIE LEE KRAMER JT/RS 1/2 & CURTIS E. & CONNIE S. HANSEN JT/RS 1

Description:

APT #105 ---> hole in ceiling in bathroom - leaking water from upper apartment leaking into shower. no sink in bathroom. Hasnt been installed for past month.

Case Violations

Case Number: T12DV06325
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 8
Violation Date Code Statue
08/01/2012 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
08/01/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
08/01/2012 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (1) Dwelling units shall be provided with one or more bathrooms equipped with a water closet, lavatory, and either a bathtub or shower. The number of water closets and lavatories for commercial buildings shall be determined by the International Building Code based on the use of the building. Each sink, bathtub and shower shall have hot and cold running water as necessary for its normal operation and use.
08/01/2012 T.C. Ch. 16, Sec. 16-11(f)(1) Every wall or vertical support must be sufficient to carry imposed loads safely, and must not lean, buckle, or split due to defect or lack of maintenance.
08/01/2012 T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration.
08/01/2012 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
08/01/2012 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
08/01/2012 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.

Outstanding Inspections

Case Number: T12DV06325
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
09/12/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX WNAVARRO Item closed
09/12/2012 NPO(PL)-PLUMBING SYSTEM & FX WNAVARRO Item closed
09/12/2012 NPO(HC)-COOLING WNAVARRO Item closed
09/12/2012 NPO - SMOKE ALARMS WNAVARRO Item closed
09/12/2012 NPO - EXT. BUILDING MAINTENANC WNAVARRO Item closed
09/12/2012 NPO - INT. BUILDING MAINTENANC WNAVARRO Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV06325
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 3
End Date Description Inspector Results Comments
07/31/2012 INSP - INITIAL CODE ENFORCMENT WNAVARRO Approved Visited site, met tenant, inspected, found as follows, front door showing lite and allowing penetration of out door elements in unit, cieling in bathroom above the tub/shower has a two by three foot open area showig second floor plumbing, electrical and exposed insulation, bathroom sink/ basin installed but no plumbing or connected to water sewer, sheetrock surrounding the sink/basin is installed but not finished, also smoke detector there are none, electrical outlets are to the point of not securing the appliance cords and are causing a safety hazard, there is a swamp cooler register that is loose and is a safety hazard to the tenants, called manager and explained to him that this needed to be abated and that the owners would recieve a notice of violation, took pictures.
09/12/2012 INSP - FOLLOW UP CODE ENFORCE WNAVARRO Approved Maintenence called and stated that they unit is complete, case closed abated
09/12/2012 INSP - FOLLOW UP CODE ENFORCE WNAVARRO Approved Visited site, inspected, unit is not complee, will charge reinspection fee, follow up to be on 09/14/2012.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T12DV06325
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
08/02/2012 CONTACTED BY MAILING
08/02/2012 NOTICE OF VIOLATION ISSUED
09/20/2012 VIOLATION CLOSED
09/13/2012 REINSPECTION FEE - FIRST

Documents

File Name Document Type  
4961 S PARK AVE NOV.PDF DOCUMENTS VIEW
None IMAGES VIEW