Case: T12DV06294
Case Details
Entered Date:
07/27/2012
Applicant:
KYLE & ANGELA HANSEN CP/RS
Description:
HOUSE FIRE/ TFD REQUEST FOR INSPECTOR
Outstanding Inspections
Case Number: T12DV06294
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/03/2012 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | MROMERO | Item closed | |
| 10/03/2012 | NPO - EXT. BUILDING MAINTENANC | MROMERO | Item closed | |
| 10/03/2012 | NPO - INT. BUILDING MAINTENANC | MROMERO | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV06294
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/27/2012 | INSP - INITIAL CODE ENFORCMENT | GGOODMAN | Approved | VISITED SITE, MET WITH TFD FIRE INVESTIGATOR WAYNE CUMMINGS AND OWNER KYLE HANSEN (TFD CAPTAIN). THE ENTIRE STRUCTURE IS A TRI-PLEX WITH A CARPORT ON THE SOUTH END OF THE TRIPLEX. OWNERS FROM UNIT #2 HAD THEIR CAR PARKED IN THE CARPORT, IT STARTED ON FIRE OR EXPLOADED WHICH IN TURN TORCHED THE CARPORT. STRUCTURE WAS APPROX 18 FT X 18 FT, THE STRUCTURE WAS COMPLETELY DAMAGED BY FIRE. THE NORTH CARPORT WALL DIVIDED THE CARPORT FROM THE TRIPLEX STRUCTURE, UNIT #3. EXTERIOR FOAM LATHE MELTED LEAVING THE STUCCO UNATTACHED TO THE WALL STUDS. STUCCO WILL PROBABLY NEED TO BE REMOVED AND WALL LATHED AND WIRED AND RESTUCCO'ED. DRYWALL HAD BEEN REMOVED FROM THAT EXTEROR WALL. MOST OR ALL OF THE DRYWALL ON THE SOUTH WALL (BOTH BEDROOMS) HAD BEEN REMOVED AN AREA APPROX 30 FT X 8 FT. AND SMALL PORTIONS OF THE CEILING. ELECTRICAL WIRING IN THE SOUTH WALL HAD BEEN FIRE DAMAGED. TFD TURNED POWER OFF AT THE SERVICE DISCONNECT. TENANTS JUST RENTED THE UNIT, HAD MOVED IN THEIR BELONGING BUT WERE NOT YET OCCUPYING THE UNIT AND NOT THERE AT THE TIME. OWNER ASKED THAT BATHCREST BOARD THE STRUCTURE. EMERGENCY NOV, ORDER TO VACATE WAS ISSUED TO AND SIGNED FOR BY THE OWNER, UNIT WAS POSTED UNFIT TO OCCUPY. S/W GAS REPORTED THAT THERE WAS NO GAS TO THE BUILDING.THEY DID CONDUCT A LINE TEST. pERMITS WERE REQUIRE DUE TO THE EXTENT OF THE WORK. FRAMING / ANCHORS, DRYWALL, ELECTRICAL AND STUCCO REPAIRS WILL ALL BE INCLUDED ON THE PERMIT,ROOF SHEATHING AND NAIL OFF. |
| 10/03/2012 | INSP - FOLLOW UP CODE ENFORCE | MROMERO | Approved | FU SHOWS ALL WORK COMPLETED. PERMIT IN FINAL STATUS. CLOSE |
Completed Activity Special Conditions
Case Description - RESIDENTIAL FIRE
Case Number - T12DV06294
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 07/30/2012 | NOTICE OF VIOLATION ISSUED |
| 10/10/2012 | VIOLATION CLOSED |
| 11/29/2012 | SEC LETTER OF BILLING FOR $??? SENT TO OWNERS |
| 10/14/2013 | SEC BILLING - PAID |
| 07/30/2012 | STRUCTURE SECURED BY ??? |
| 07/30/2012 | CALLBACK |