Case: T12DV06045
Case Details
Entered Date:
07/20/2012
Applicant:
KENNETH D MC LAUGHLIN & MARIA THERESA TOSTES-RIBEIRO
Description:
RESIDENCE FLOODED
Case Violations
Case Number: T12DV06045
Case Status: COMPLIAN
Case Description: CONDEMNATION
Total Violations: 2
| Violation Date | Code Statue |
|---|---|
| 07/20/2012 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 07/20/2012 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (1) Dwelling units shall be provided with one or more bathrooms equipped with a water closet, lavatory, and either a bathtub or shower. The number of water closets and lavatories for commercial buildings shall be determined by the International Building Code based on the use of the building. Each sink, bathtub and shower shall have hot and cold running water as necessary for its normal operation and use. |
Outstanding Inspections
Case Number: T12DV06045
Case Status: COMPLIAN
Case Description: CONDEMNATION
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2012 | NPO(PL)-PLUMBING SYSTEM & FX | AVINDIOL | Follow-up inspection | |
| 12/20/2012 | NPO - WORK WITHOUT PERMIT | AVINDIOL | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV06045
Case Description: CONDEMNATION
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2012 | INSP - INITIAL CODE ENFORCMENT | WNAVARRO | Approved | VISITED SITE,MET TUCSON FIRE ON SITE, INSPECTED, FOUND AS FOLLOWS, FIRST FLOOR HAD STANDING WATER ON FLOOR, CIELING HAD COLLASPED IN SEVERAL AREAS, WATER SEAPING THRU CEILING LIGHT FIXTURES, INSULATION ABSORBED AND FALLING OUT OF JOISTS, INSPECTED SECOND FLOOR AND FOUND AS FOLLOWS, STANDING WATER, FLOOR BUCKLED, WATER DAMAGE ON SHEETROCK, ELECTRIC WAS SHUT OFF AT SERVICE ENTRANCE. MET WITH NEXT DOOR NEIGHBOR AND HAS KEY AND HAS BEEN TAKING CARE OF RESIDENCE, EXPLAINED TO HIM THAT UNIT IS CONDEMNED AND OWNER WILL BE HAVE THE ABILITIY TO ENTER UNIT TO GET BELONGINGS OUT.TUCSON FIRE HAD SHUT WATER OFF. TOOK PICTURES, WILL WRITE NOTICE OF VIOLATION |
| 12/20/2012 | INSP - FOLLOW UP CODE ENFORCE | AVINDIOL | Approved | 12/20/12 ON SITE OWNERS NOT HOME // WORKERS ON SITE ALLOWED ME IN // IN REMODELING MODE MOVING FORWORD UNDER PERMIT BEING WORKED LAST INSPECTION ON 12/17/12 INTERMEDIATES FOR ELECTRICAL/PLUMBING/MECHANICAL APPROVED ALONG WITH FRAMING APPROVAL // WILL CONTINUE TO MONITOR // AV |
Completed Activity Special Conditions
Case Description - CONDEMNATION
Case Number - T12DV06045
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 07/24/2012 | CONTACTED BY MAILING |
| 07/24/2012 | NOTICE OF VIOLATION ISSUED |
| 08/16/2013 | VIOLATION CLOSED |