Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

07/16/2012

Applicant:

JERRY D. WILSON

Description:

COOLER LEAKING AND CAUSING MOLD IN THE HOUSE. MULTIPLE MINIMUM HOUSING ISSUES.

Case Violations

Case Number: T12DV05895
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
07/26/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
07/26/2012 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
07/26/2012 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
07/26/2012 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element.
07/26/2012 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.

Outstanding Inspections

Case Number: T12DV05895
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
09/13/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX RMENDOZA Item closed
09/13/2012 NPO(PL)-PLUMBING SYSTEM & FX RMENDOZA Item closed
09/13/2012 NPO(PL)-WATER HEATERS RMENDOZA Item closed
09/13/2012 NPO - EXT. BUILDING MAINTENANC RMENDOZA Item closed
09/13/2012 NPO - INT. BUILDING MAINTENANC RMENDOZA Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV05895
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/18/2012 INSP - INITIAL CODE ENFORCMENT RMENDOZA Approved Hall ceiling shows signs of leaking and water damage. Kitchen sink is leaking at the faucet. Rear porch shows signs of water damage. Possibly for a leaking cooler. Electrical conduit under the rear porch is miss a strap and is sagging above the door area. Water heater lack a trpv pipe. Flue pipe is not attached. 90 degree bend on the exhaust pipe. Roof around the cooler area is deteriorated.
09/13/2012 INSP - FOLLOW UP CODE ENFORCE RMENDOZA Approved Water heater repaired. Kitchen faucet replaced. Conduit secured. Rear porch sanded and repainted. Hallway ceiling repaired.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T12DV05895
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
07/16/2012 CONTACTED BY PHONE
07/26/2012 CONTACTED BY MAILING
07/26/2012 NOTICE OF VIOLATION ISSUED
09/17/2012 VIOLATION CLOSED

Documents

File Name Document Type  
5302E26THNOV1.PDF DOCUMENTS VIEW